11.

BEFORE FIRST USE

Vacuum assembly and testing
Before activating the required commands and
beginning to use the device, check that:
-
No foreign elements are present within the
container: if necessary, open the lateral closure
hooks, lift the device's cover and remove any
such objects before use. Once the container
has been emptied, re-attach the device' s cover
and lock its closure hooks, which guarantee an
air-tight seal;
-
The filter bag for the aspiration of MAK-dusts
has been installed: the bag is equipped with a
membrane seal which must be fitted over the
internal slot of the device' s aspiration opening;
the bag is also equipped with an ecological
closure for its subsequent safe removal;
vaccum in category H dust it is possible with
integral filtering system applied.
-
The aspiration tube has been connected to the
aspiration opening by means of the coupling
sleeve on the tube itself.
Insert the electrical power cable' s plug into an
electrical system outlet that is equipped with the
necessary protection devices. Activate the device using
the appropriate controls.
CODE
DESCRIPTION
5830.0266
Filter bag
5830.0739
Filter bag
5830.0678
Primair filter
5830.0736
Primair filter
5830.0737
Primair filter
5830.0679
Hepa filter
© 2021 Dehaco B.V. • Manual • Mamba Stofzuiger/Staubsauger/Dust Vacuum Cleaner/ Aspirateur / Airadora de polvo _2021-10_v3.0_NL_DU_EN_FR
SAFETY INDICATIONS MAMBA VACUUM CLEANER CLASS-H - EN
Initial working phase check
Before beginning to vacuum dusts with MaK values,
check that the filters fit properly within the device and
that they are positioned correctly.
Once the vacuum has been activated, block the
aspiration tube and check whether an acoustic signal
sounds: the acoustic signal turns on if the speed of the
air within the tube falls beneath 20m/sec.
In normal usage conditions, the acoustic signal turns
on to signal a reduction in pressure: the filter must be
cleaned or the bag must be replaced. .

USE OF THE DEVICE

ATTENTION!
The aspiration of flammable dusts/substances is
forbidden.
The sector' s reference standard, EN 60335-2-69/
A1:2004, lists the dusts which present a risk of
explosion when brought into contact with ignition
sources.
A filter bag must always be inserted into the container
when the device is to be employed for vacuuming dry
substances with MaK values.
For innocuous dusts, a lower-performance paper filter
bag is also available.
Filter bag reference table:
VACUUM MODEL
Dehaco Mamba 121
Dehaco Black Mamba 150 / 277
Dehaco Mamba 121
Dehaco Black 150
Dehaco Black 277
Dehaco Mamba 121 / Black 150
5830.0738
Dehaco Black 277
ATTENTION!
The collection bags must not be filled past of
their capacities. When the bag is fitted onto the
aspiriation opening, make sure that the amount
of dust contained within it does not exceed of the
total height of the bag itself. Check periodically
during use.
Do not vacuum liquids or particularly humid
substances while the bag filters are installed upon
the vacuum.
Hepa filter