Two-Hand Control (switch 1 in position 5)

4 pairs of 2-hand buttons Typ III A or 2 pairs of 2-hand buttons Typ III C
according to EN ISO 13851 can be connected in this function. The number
of connected button pairs has to be selected on the device.
K1 and K2 can only be activated, if 3 conditions are fulfilled:
- First all button pairs have to be in initial position.
- Both buttons of 1 pair have to be pressed within 0.5 sec.
- All connected pairs have to be operated within 15 s.
If changeover contacts are used in the 2-hand buttons the switchover time
has to be less then 50 ms. If it is longer the outputs K1 and K2 are switched
off and the unit gives failure code 7. This failure is stored and can only be
reset by disconnecting the auxiliary supply.

Function Diagram

Auxiliary
voltage (A1/A2)
Button 1 S1 (S11/S12)
Button 1 S2 (S13/S14)
Button 2 S1 (S21/S22)
Button 2 S2 (S23/S24)
K1/K2 (13-14,
23-24, 33-34)
48 (no button activated)
58 (all buttons activated)
<0,5s
<15s
: off
: on
: flashing
Two-hand control, 2 pairs of buttons with 2 NO contacts each

Set-Up Instructions

The device has to be connected as shown in the application examples.
When connecting the push-buttons in parallel or in series the safe function
of the relay is disabled. The buttons must be designed and installed in
a way, that it is not possible to manipulate or to operate them without
intention.
The distance between push buttons and dangerous area must be chosen
in a way that it is not possible to reach the dangerous area after release of
one button before the dangerous movement comes to standstill.
The safety distance "S" is calculated with the following formula:
S = V x T + C
a) moving speed of person V = 1 600 mm/s
b) stopping time of the machine T (s)
c) Additional safety distance C = 250 mm
If the risc of accessing the dangerous area is prohibited while the push
buttons are pressed e.g. by covering the buttons, C can be 0. The minimum
distance has to be in this case 100 mm. See also EN ISO 13851.
Settings on switch 10
Terminal designation
0,5s
15s
M8444
Semiconductor outputs
42
Switch
Number of
10
button pairs
0
1
1
2
2
3
3
4
4
1
5
2
6
1
7
2
8
3
9
1
Pair of buttons with
Pair of buttons with
Ter-
minal
2 NO contacts each
2 C/O contacts each
S11
Pair 1, button S1
S12
common connector
S14
common connector
Pair 1, button S2
S13
S21
Pair 2, button S1
S22
common connector
S24
common connector
S23
Pair 2, button S2
S31
S32
Pair 3, button S1
common connector
S34
common connector
S33
Pair 3, button S2
S41
S42
Pair 4, button S1
common connector
S44
common connector
S43
Pair 4, button S2
Output
Flashing signal
Open gate, e-stop loop open
48
or failure in feedback circuit or
failure on simulation button
58
Press acknowledge button.
Type of button
Feedback circuit for
contacts
external contactors
2 NO contacts
no
2 NO contacts
no
2 NO contacts
no
2 NO contacts
no
2 C/O contacts
no
2 C/O contacts
no
2 NO contacts
yes
2 NO contacts
yes
2 NO contacts
yes
2 C/O contacts
yes
Feedback circuit for
external contactors
Pair 1, button S1,
NO contact
Pair 1, button S1,
Pair 1, button S1,
Pair 1, button S1,
contact NC
Pair 1, button S2,
NC contact
Pair 1, button S2,
Pair 1, button S2,
Pair 1, button S2,
NO contact
Pair 2, button S1,
NO contact
Pair 2, button S1,
Pair 2, button S1,
Pair 2, button S1,
NC contact
Pair 2, button S2,
NC contact
Pair 2, button S2,
Feedback circuit
Pair 2, button S2,
Acknowledge button
Pair 2, button S2,
NO contact
Continuous signal
All buttons in initial
position. For a new start
all buttons have to be
activated according to
the starting conditions.
All buttons are
activated,
K1, K2 are energized.