Safety Gates (switch 1 in position 3)

With switch 10 the maximum number of gates is selected. Open (unused)
inputs (S_1/S_2 and S_3/S_4) have to be linked with a wire bridge. If gate
inputs are not used the type of control has to be with simulation button.
K1 and K2 can only be activated, if all connected gates have been opened
and closed again. Both gate contacts have to be operated within 3 s. If
the time difference is longer, the gate has to be opened before it can be
closed again. When all gates are closed the unit can also be activated by
an external connected Simulation button.
If changeover contacts are used on the gate switches the switchover time
has to be less then 50 ms. If it is longer the outputs K1 and K2 are switched
off and the unit gives failure code 7. This failure is stored and can only be
reset by disconnecting the auxiliary supply.

Function Diagram

Auxiliary
voltage (A1/A2)
Gate 1 S1 (S11/S12)
Gate 1 S2 (S13/S14)
Gate 1 S3 (S21/S22)
Gate 2 S1 (S23/S24)
Gate 2 S2 (S31/S32)
Gate 2 S3 (S33/S34)
Simulation button
(S43/S44)
K1/K2 (13-14,
23-24, 33-34)
48 (gate open
or failure)
58 (all gates closed)
: off
: on
: flashing
Gate monitor, 2 gates with 3 NO contacts for each gate, Simulation button
Semiconductor outputs
Output
Flashing signal
Open gate or failure in feedback
48
circuit or in start circuit
Gates are closed but starting
58
conditions not fulfilled
Settings on switch 10
Switch
NO contacts must be closed when gate is closed, NC contacts must be
open when gate is closed.
Terminal designation
Ter-
minal
S11
S12
S14
>3s
S13
M8437
S21
S22
S24
Continuous signal
S23
S31
Gates are closed and
contacts K1, K2
S32
are active
S34
S33
S41
S42
S44
S43
37
Number and
Number
type of
10
of gates
gate switches
0
4
2 NO contacts
1
3
2 NO contacts
2
2
2 C/O contacts
3
1
2 C/O contacts
4
2
3 NO contacts
2 C/O contacts
5
1
+ 1 NO contact
6
3
2 NO contacts
7
1
2 C/O contacts
8
2
3 NO contacts
2 C/O contacts
9
1
+ 1 NO contact
Max. 2
1 gate
gates with
with 2 C/O
3 NO gate
+ 1 NO gate
contacts
contact
gate 1, S1
gate 1, S1
NO contact
gate 1, S1
common
connector
gate 1, S1
common
gate 1, S2
connector
gate 1, S1
NC contact
gate 1, S2
NC contact
gate 1, S3
gate 1, S2
common
connector
gate 1, S2
common
gate 2, S1
connector
gate 1, S2
NO contact
gate 2, S2
gate 1, S3
not
gate 2, S3
connected
not
not
connected
connected
Feedback circuit
Simulation
for external
button
contactors
no
no
yes
no
no
no
yes
no
yes
no
yes
no
yes
yes
yes
yes
yes
yes
yes
yes
Feedback
Max. 4
Max. 2
circuit for
gates with
gates with
external
2 NO gate
2 C/O gate
contacts
contacts
contacts
simula-
tion
gate 1, S1
NO contact
gate 1, S1
gate 1, S1
common
connector
gate 1, S1
common
gate 1, S2
connector
gate 1, S1
NC contact
gate 1, S2
NC contact
gate 2, S1
gate 1, S2
common
connector
gate 1, S2
common
gate 2, S2
connector
gate 1, S2
NO contact
gate 2, S1
NO contact
gate 3, S1
gate 2, S1
common
connector
gate 2, S1
common
gate 3, S2
connector
gate 2, S1
NC contact
gate 2, S2
NC contact
Feedback
gate 4, S1
gate 2, S2
circuit
common
connector
gate 2, S2
common
Simulati-
gate 4, S2
connector
on button
gate 2, S2
contact NO
BH 5910 / 23.06.22 en / 594A

Publicité

Table des Matières
loading

Table des Matières