FUXTEC FX-FSR162 Mode D'emploi Original page 55

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Original Bedienungsanleitung FUXTEC FX-FSR162_de_en_fr_ita_rev01
36.
Troubleshooting
1) Difficulties during commissioning
Situation
Spark plug
No ignition
spark
Other
Compression
Weak
ignition
spark
Carburettor does not
pump oil anymore.
Regular oil supply
but weak
compression
Regular oil supply
and good ignition
spark
2) Difficulties during operation
Situation
Cause
Choke is in "COLD START" position, the
The engine does
exhaust system is blocked no air supply,
not reach a
moving elements worn, ignition spark
speed
weak too large valve clearance, cylinder
head sooty
Operating
Lines to carburettor blocked Spark plug
materials are
spacing incorrect
leaking
Engine
Wrong choke position,
Noises
Camshaft damaged
Carburettor
Failure of the check valve on the tank cap
leaking
Carburettor gasket is worn out
Cause
Carbon deposit between the
diodes of the spark plug
Ignition coil defective flywheel
magnet too weak
Too much gasoline in the
combustion chamber, lousy fuel or
water in the tank
Oil line blocked
Piston rings worn, spark plug not
screwed down, cylinder head not
tight wrong valve clearance or
ignition timing.
Poor contact between ignition cap
and spark plug
55
Solution
Clean the spark plug.
Adjust the gap
0.6~0.7mm, replace
the spark plug
Replace the ignition
coil or flywheel
Remove the spark
plug and allow to dry,
replace fuel.
Cleaning the
carburettor and
cleaning the pipes
Replace screw tight
replace or adjust
Replace or check
Solution
Open choke, replace exhaust system
Check or replace ignition coil, adjust
flywheel, spark plug
Replace lines and carburettor Adjust
gap dimension
Check/replace camshaft
Replace the fuel filler cap
Replace carburettor or gasket

Publicité

Table des Matières
loading

Table des Matières