Trailer Id Module Test - FloTech FT555F Mode D'emploi

Système de test automatique antidébordement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FloTech FT555F Automatic Overfill System Tester

TRAILER ID MODULE TEST

This test will test the Trailer ID Module and report the 12 digit
serial number stored inside the ID module. If there is no trailer ID
module or the test fails the screen will show "TIM not found"
Step 1) Move the J-Slot thumb screws to the correct holes to match
the type of socket to be connected. Follow the "O" and "T"
markings on the plug body.
Step 2) Connect the FT555F Automatic Tester to the trailer socket.
Step 3) Press the ON/OFF button to turn on the FT555F Automatic
Tester. When "Press Key" screen appears press "TEST SELECT"
button five times so the "Trailer ID Module Test" screen appears.
Step 4) Press the "GO" button to start the test. When the test is
complete the screen will report the 12 digit serial number or show
"TIM not found".
Step 5) Press the TEST SELECT" button to move on to a new test,
press "GO" to restart the test, or press the "ON/OFF" button to
turn the tester off.
Page 16
10784PA REV C
FT555F Truck Tester

Publicité

Table des Matières
loading

Table des Matières