Connecting the Duct
● Install a circular duct to outlet and secure it with duct tape or clamps.
● Install the duct to the outlet with a gradient 1°~2° to the outside as shown.
● The ducting from this FAN to the outside of the building has a strong effect on
the air flow, noise and energy use of the fan. Use the shortest, straightest duct
routing possible for best performance, and avoid installing the FAN with smaller
ducts than recommended. Insulation around the ducts can reduce energy loss
and inhibit mold growth. Fans installed with existing ducts may not achieve their
rated airflow.
● 4 in (10.16 cm) round is recommended for best performance.
● Ensure duct joints and exterior penetrations are sealed with caulk or other
similar material to create an air-tight path, to minimize building heat loss and
gain, and to reduce the potential for condensation.
● Place/wrap insulation around duct and/or FAN in order to minimize possible
condensation buildup within the duct, building heat loss and gain.
INSULATION*
(Place around and
over Fan Housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
housing.
ROUND
DUCT*
*Purchase
separately.
Seal duct
joints with
ROUND
tape.
ELBOWS*
OR
6
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)