WARNING: Disconnect the AC power before any work is done to any part of
the circuit ReVent
seek the services of a qualified licensed electrician.
WARNING: Copper to copper only. Do not use aluminum wire.
WARNING: Follow all local electrical and safety codes, and NEC (National
Electrical Codes).
CAUTION: If your house wires do not match these colors, determine what
each house wire represents before connecting. You may need to consult a
qualified licensed electrician to determine this safely.
6.) Disconnect FAN motor from electrical enclosure. Remove the electrical cover
set screw and slide open the electrical enclosure.
unplug fan
connector
remove set
screw
7.) Connect wiring using the provided WIRE NUTS. Match wire colors as shown:
line
ground
FAN
ground
housing
ground
is connected to. If you do not understand this warning,
®
line in
neutral
neutral
16
slide
line in
FAN
FAN
WIRE NUT
Qty:3