Adjustment Of The Float Switch; Operational Start-Up - FLORABEST FTS 1100 C3 Traduction Du Mode D'emploi D'origine

Pompe d'évacuation des eaux chargées
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Œ
Outlet with a 1½" internal thread on
the pump for connection of the angle
adapter (10) or for direct connection of
a hose with a 1½" external thread;
Outlet with 1½" external thread at the

bracket adapter (10) for connection of
the reducer (9) or a 1½" screw connec-
tion;
Outlet on reducer (9) for connection of
Ž
a 1¼" or 1½" hose as a compression
joint (fixing with a hose clamp);
Outlet with 1" external thread at the

reducer (9) for connection of a 1" screw
connection;
Outlet with 1½" thread at the reducer

(9) for connection of a 1"hose as clamp
connection (fixing with a hose clamp).
Note that the particle size may
be max. 19 mm if the reducer
(Ø 19.3 mm) is used, otherwise
the reducer and hose can become
blocked.
Adjustment of the float
switch
The float switch (
can be started up immediately.
In the case of stationary installation, check
regularly (no less then once every three
months) that the float switch is working.
The ON and OFF switching point of the
float switch can be adjusted by changing
the position of the float switch in the float
switch grating. Please check the following
points before start of operation.
The float switch must be attached so
that the switching point ON level and
the switching point OFF level can be
reached easily and with little expenditure
of energy. Check this by placing the
pump into a vessel filled with water and
7) is adjusted so that it
lift the float switch carefully by hand and
then lower it again. In this case, you can
see whether the pump switches on and
off.
Also ensure that the separation distance
between the float switch head and the
float switch latching mechanism (
is not too small. In the case of a separa-
tion distance which is too small, trouble-
free functioning cannot be guaranteed.
During the adjustment of the float switch,
ensure that the float switch does not con-
tact the floor before the pump switches
off.
There is a risk of dry running if the
float switch cable is selected to be
too long

Operational start-up

• Check that the pump is standing
firmly on the bottom of the shaft or
hung up safely.
• Check whether the pressure line
has been attached correctly and
the unused pump outlet is fully
closed.
• Avoid that the pump runs dry.
Regularly check the function of
the float switch. In case of non-
observance or if the pump runs
dry, guarantee and liability claims
are invalidated.
• Check that the electrical connec-
tion is 230 V ~50 Hz
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A, RCD
switch). Insert the pump plug into
the plug socket and the pump is
ready for operation.
• Make sure that moisture or water
GB
8)
31