Areas of Application

The dirty water submersible pump is a drain-
age pump and designed for transporting
water and sewage water (max. particle size
35 mm) up to a temperature of max. 35 °C.
It is suitable e.g. for pumping around and
pumping out basins and containers, for
pumping out flooded cellars, and for extract-
ing water from wells and shafts. This equip-
ment is not suitable for industrial use. Indus-
trial use will invalidate the guarantee.
Any other use, not expressly authorised in
these instructions, may cause damage to the
equipment and represent a serious risk for
the user.
The pump is not suitable for continuous oper-
ation. Continuous operation reduces the du-
rability and shortens the guarantee period.
The operator or user is responsible for ac-
cidents or damage to other people or their
property.
The manufacturer shall not be liable for dam-
ages caused by use other than for which
the equipment is intended or by incorrect
operation.

General Description

The diagram of the most important
functional elements can be found
on the foldout side.

Scope of Delivery

Carefully unpack the appliance and check
that it is complete. Dispose of the packaging
material correctly.
-
Fully assembled dirty water submersible
pump
-
Angle adapter
-
Reducer
-
8 m nylon cord
-
Instruction Manual

Functional description

The dirty water submersible pump has a
stainless steel casing, a stable suction foot
and a non-corrosive motor shaft. The pump
is fitted with a float switch, which automati-
cally switches the equipment on or off.
The motor is protected from overload by a
thermal safety switch.
Please refer to the following descriptions for
the function of the operating parts.

Overview

1 Round handle
2 Pump housing
3 Pump outlet
4 Floor plate
5 Foot part
6 Mains connection cable
7 Float switch
8 Float switch grating
9 Reducer
10 Angle adapter
11 8 m nylon cord

Technical Data

Rated voltage ................... 230 V~, 50 Hz
Rated power input/
Power consumption ..................... 1100 W
Max. discharge rate (Q max) .... 20000 l/h
Max. discharge head (H max) ............. 9 m
Max. depth of immersion .................... 7 m
Max. water temperature (T max) ....... 35 °C
Hose connection ................ 1", 1¼ ", 1½ "
Max. foreign body size ..................35 mm
Switching point level:
ON ............................ approx. 520 mm
OFF ........................... approx. 230 mm
Mains cable .................................... 10 m
Weight (incl. accessories) ............. 6.18 kg
Safety class ............................................ I