Installing An Accessory; Pre-Operation Inspection - RIDGID micro CA-100 Manuel De L'opérateur

Masquer les pouces Voir aussi pour micro CA-100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
micro CA-100 Inspection Camera
Figure 5 – Cable Connections
3' and 6' cable extensions are available to
increase the length of your cable up to 30' in
length. To install an extension, first remove the
camera head cable from the display unit by
loosening the knurled knob. Connect the ex-
tension to the handheld as described above
(Figure 5) . Connect the keyed end of the
camera head cable to the slotted end of the
extension and finger tighten the knurled knob
to hold the connection in place.

Installing An Accessory

The three included accessories, (mirror, hook
and magnet) (Figure 1) all attach to the imager
head the same way.
To connect, hold the imager head as shown in
Figure 6 . Slip the semicircle end of the acces-
sory over the flats of the imager head as
shown in Figure 6 . Then rotate the accessory
a 1/4 turn so the long arm of the accessory is
extending out as shown (Figure 6) .
Figure 6
Pre-Operation
Inspection
WARNING
Before each use, inspect your inspec-
tion camera and correct any problems
to reduce the risk of serious injury from
electric shock and other causes and
prevent tool damage.
6
Slot
Key
Accessory
1. Make sure the unit is OFF.
2. Remove the battery holder and inspect it
and batteries for signs of damage. Re-
place batteries if necessary. Do not use
inspection camera if batteries are dam-
aged.
3. Clean any oil, grease or dirt from the e-
quipment. This aids inspection and helps
prevent the tool from slipping from your
grip.
4. Inspect micro CA-100 Inspection Camera
for any broken, warn, missing, misaligned
or binding parts or any condition which
may prevent safe and normal operation.
5. Inspect the camera head lens for conden-
sation. To avoid damaging the unit, do not
use the camera if condensation forms
inside the lens. Let the water evaporate
before using.
6. Inspect the full length of the cable for
cracks or damage. A damaged cable
could allow water to enter the unit and in-
crease the risk of electrical shock.
7. Check to make sure the connections be-
tween the handheld unit, extension ca-
bles and imager cable are tight. All con-
nections must be properly assembled
for the cable to be water resistant. Con-
firm unit is properly assembled.
8. Check that the warning label is present,
firmly attached and readable.
Figure 7 – Warning Label
9. If any issues are found during the in-
spection, do not use the inspection cam-
era until it has been properly serviced.
10. With dry hands, re-install the battery hold-
er making sure to fully insert.

Publicité

Table des Matières
loading

Table des Matières