Power Supply; Selecting The Operating Mode; Switching On/Off; Level Adjustment - IMG STAGELINE STA-2200 Mode D'emploi

Masquer les pouces Voir aussi pour STA-2200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
The Speakon jack of the output L-CH (11) is ad-
ditionally provided with the signals of the right
output R-CH so that it is also possible to connect
both speakers via a 4-pole cable to this jack .
For bridge mode, connect the positive con-
tact of the speaker to the positive terminal (13) of
the left output L-CH and the negative contact of
the speaker to the positive terminal of the right
output R-CH [see fig . 2] . (By the signal inversion
in bridge mode, the positive terminal of the right
output becomes the negative connection for the
speaker .) The speaker can alternatively also be
connected to the Speakon jack L-CH (11) . Ac-
cording to fig . 2, connect the positive terminal
of the speaker to contact 1+ and the negative
terminal to contact 2+ of the plug .
Table fig . 3 also shows possibilities of con-
nection for several speakers to one output . In
each case it is stated which power rating (P
each speaker must have as a minimum with the
corresponding impedance (Z) . When intercon-
necting several speakers, special attention has to
be paid to the correct connection of the positive
and negative terminals .

5.3 Power supply

For power supply, use the mains cable provided
to connect the mains jack (14) to a mains socket
(230 V/ 50 Hz) . First connect the PowerCon plug
to the mains jack and turn it clockwise until
it locks and then connect the mains plug to a
socket . To separate it from the mains, first dis-
connect the mains plug and then, for removing
the PowerCon plug, retract its latch lock and turn
the plug counter-clockwise .
6
Operation

6.1 Selecting the operating mode

Select the desired operating mode with the DIP
switches MODE Nos . 1 to 6 (9):
Stereo mode – display:
MODE STEREO
In stereo mode, both channels are operated in-
dependently of each other .
switch configuration
STEREO
Parallel mode – display:
MODE PARALLEL
Parallel mode is recommended to provide PA
applications e . g . for two rooms with the same
mono signal and to be capable of adjusting the
volume individually .
The input signal is internally switched from
the left channel additionally to the right channel .
A signal at the right input is ignored . The volume
is separately adjusted for both outputs .
switch configuration
PARALLEL
Bridge mode – display:
MODE BRIDGE
The bridge mode (BRIDGE) is used to obtain a
higher power at one speaker . For this purpose,
both amplifier channels are combined to one
mono amplifier: The input signal of the left chan-
nel is additionally switched to the right chan-
nel in an inverted way . Thus, the voltage at the
output is doubled if the speaker is connected
for bridge mode, as described in chapter 5 .2 . A
signal at the right input is ignored . The volume
is adjusted with the left control (1) together for
both outputs .
switch configuration
BRIDGE
6.2 Filter
The integrated filter can be used as a cross-
over network for 2-way speaker systems (sub-
woofer / satellite) . Select the function correspond-
ing to the connected speaker with the switch
FILTER (10) .
Position
Filter
Low pass filter with −6 dB at 120 Hz for
SUBWOOFER
bass speakers
High pass filter with −6 dB at 120 Hz for
SATELLITE
mid-high range speakers
FULLRANGE
No filter for full range speakers
6.3 Switching on / off
To prevent loud switching noise, always switch
on the power amplifier in an amplifier system
after all other devices have been switched on
)
and switch it off first after operation . Prior to
min
first switching-on, set the controls (1 and 5) to
the left stop to "−80 dB" .
Switch on the amplifier with the POWER
switch (6) . The ACTIVE LEDs (2, 4) serve as a
power indication and the display (3) shows the
selected operating mode . After switching-on, the
red LEDs PROTECT (2, 4) light up for a short time .
During this time, the switch-on delay is activated
to protect the speakers .

6.4 Level adjustment

Adjust the output of the mixer or preamplifier to
its rated level (0 dB) or the maximum undistorted
output signal . Turn up the controls (1 and 5) until
the maximum desired volume is reached . The
LEDs "−25 dB", "−20 dB", and "−15 dB" (2, 4)
show the adjusted input level . If the red LEDs
LIMITER light up, the limiter circuit is active and
prevents overload of the amplifier . In this case
slightly turn back the controls .
CAUTION Never adjust a very high volume .
Permanent high volumes may
damage your hearing! Your ear
will get accustomed to high vol-
umes which do not seem to be that
high after some time . Therefore,
do not further increase a high vol-
ume after getting used to it .

6.5 Groundlift switch

If an interfering hum noise can be heard without
a music signal, a ground loop may be the reason
for this . Ground loops may occur when two de-
vices have contact both via the signal ground and
via the earthed conductor of the power supply or
a conductive connection of the housings in the
rack . To separate the ground loop thus occurring,
set the DIP switches No . 7 and No . 8 (9) from the
upper position to the lower position .
switch configuration
Groundlift
7
Protective Circuits
The protective circuits are provided to prevent
damage to the speakers and to the amplifier . The
integrated level limiter reduces the input signal
when the limit level at the output is reached .
Thus, in case of overload of the amplifier, distor-
tions can be prevented which might damage the
speakers . If the limiter is active, the LED LIMITER
(2, 4) of the corresponding channel lights up .
An additional protective circuit separates
the speakers from the output of the channel
concerned . If it is active, the corresponding red
LED PROTECT (2, 4) lights up:
1 . for a short time after switching-on (switch-on
delay)
2 . in case of overload/overheating (e . g . also by
short circuit at the output or when exceeding
the admissible output power in 2 Ω stereo /
parallel mode or 4 Ω bridge mode
3 . if a DC voltage occurs at the output
During normal operation, the temperature at
the power transistors is shown on the display (3)
separately for both channels . With higher tem-
peratures, the fan control ensures that the fan of
the channel concerned runs at a higher speed .
In case of a defect, e . g . a short circuit at an
output, the display changes to
PROT, OVERLOAD&FAULT
LED PROTECT of the channel concerned lights
up) . In this case, or if the LED PROTECT is not
extinguished after switching-on, or if the protec-
tive switch (15) has been released, the amplifier
must be switched off and the cause for the de-
fect must be eliminated . If required, reset the
protective switch by pressing it down .
8
Specifications
RMS output power
(1 kHz, 0.1 % THD + N)
Stereo, parallel at 4 Ω
Stereo, parallel at 8 Ω
Bridge mode at 8 Ω
Maximum admissible RMS output
power at lower load impedance
Stereo, parallel at 2 Ω
Bridge mode at 4 Ω
Input sensitivity for rated power at 8 Ω
Input impedance bal. / unbal.
Frequency range with 1 W at 8 Ω
High pass filter / low pass filter
Attenuation factor at 8 Ω
THD*
Channel separation*
S / N ratio with rated power at 8 Ω
*20 Hz – 20 kHz with rated power at 8 Ω
Output circuit
Ambient temperature
Power supply
Maximum power consumption
Dimensions (W × H × D)
Rack spaces
Weight
Subject to technical modification .
All rights reserved by MONACOR
GmbH & Co. KG. No part of this instruction manual
may be reproduced in any form or by any means for
any commercial use.
SHORT CIR.
(in addition, the
2 × 1100 W
2 × 700 W
2000 W
2 × 750 W
1500 W
1 V
20 kΩ / 10 kΩ
20 Hz – 20 kHz
(±0.3 dB)
120 Hz (−6 dB),
24 dB / octave
> 300
< 0.1 %
> 60 dB
> 100 dB
class H
0 – 40 °C
230 V/ 50 Hz
3600 VA
482 × 88 × 479 mm
2 U
22.5 kg
INTERNATIONAL
®
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0250490

Table des Matières