Bosch FNH180K-16 Consignes De Fonctionnement/Sécurité page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BM 2610034445 03-14_FNH180 3/27/14 11:52 AM Page 12
• To drive the nail deeper, turn the
adjustment knob "too shallow" icon, see
figure 11.
4. Reload nails as described in the "Nail
Loading" section of this manual.
5. Reconnect battery pack.
Know what is behind your
W RNING
work piece. Do not fire
nails into walls or floors without assuring
the area on the opposite side is clear. A
nail could travel through the work piece,
striking someone.
jAM CLEARING
Disconnect the battery pack
W RNING
from tool before attempting
to clear a jammed nail. Such precautionary
safety measures reduce the risk of
unintentional tool operation.
If a nail becomes jammed in the nosepiece,
follow these instructions to remove the jammed
nail:
1. Release the trigger.
FIG. 12
All manuals and user guides at all-guides.com
2. Disconnect the battery from the tool.
3. Remove nails from the magazine as
4. Open the nose of the tool by pulling quick
5. Remove the nail, using pliers if necessary.
6. Close the nose of the tool by hooking the
7. Reinsert nails into the magazine as
8. Reconnect battery.
NOTE: If the driver blade does not return to its
up position, disconnect battery and contact a
Bosch factory service center or authorized
Bosch service station.
NOTE: If nails continue to jam frequently in the
nose piece, contact BOSCH service center for
repair.
FIG. 13
-12-
described in "Nail Unloading."
release lever forward. Pull open the nose of
the tool to access the nail jam, see figure 12.
spring of the quick clear lever on the two
hooks on the nose. Press the lever closed,
see figure 13.
described in "Nail Loading".