Kohler K-10950 Mode D'emploi page 10

Masquer les pouces Voir aussi pour K-10950:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting (cont.)
Symptoms
Probable Causes
B. The wires are
C. There is water
D. The battery
2.
No water
A. The AC unit is
flow (AC).
B. The ground
C. There is a
1025498-2-E
Recommended Action
B. Remove the spout and
pinched or
verify that the wires are
damaged.
tucked inside the spout
before reassembling. If the
wires are cut or damaged,
order a new solenoid or
sensor assembly.
C. Remove the spout and
leakage on
check for corrosion on the
electrical
connections between the
components or
battery to solenoid and the
connectors.
solenoid to sensor. If
possible, clean the
terminals. If unable to
repair the connection, order
a new sensor assembly or
solenoid assembly, as
required. Inspect the O-ring
on the valve for cuts,
debris, etc. If the O-ring is
damaged, order a new
O-ring. The origin of the
leak must be investigated
and repaired. Refer to the
Maintenance Guide.
D. Replace the battery. Refer
life has
to the Maintenance Guide.
expired.
A. Plug the AC wall brick
not plugged
firmly into a working
in.
outlet.
B. Check that the breaker for
fault breaker is
the circuit used by the
tripped.
faucet is on.
C. Remove the spout and
loose
check the connection from
connection.
the AC unit to the solenoid
and from the solenoid to
sensor. Make sure that the
connector arrows are
aligned and that the
connection is secure. Refer
to the Maintenance Guide.
10
Kohler Co.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K-1095110952109531095410955

Table des Matières