Section 5. Filter Disassembly; And Assembly; Filter Element Removal - Zodiac Jandy Pro Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series, CE Single Element Cartridge Pool & Spa Filter
®
9.
After the pressure gauge has stabilized, turn the
bezel ring so that the arrow next to the word
"CLEAN" aligns with the needle of the gauge.
See Figure 7. As the filter cleans the water, and
the cartridges begin to clog the pressure begins to
increase. When the needle of the pressure gauge
aligns with the arrow next to the word "DIRTY"
on the bezel, it is time to clean the filter, see
Section 6.3. This indicates an increased pressure
of between 10 and 12 psi above original starting
pressure.
Figure 7.
Pressure Gauge with Clean/Dirty Snap
Ring

Section 5. Filter Disassembly

and Assembly

WARNING
NEVER attempt to assemble,
disassemble or adjust the filter when
there is pressurized air in the system.
Starting the pump while there is any
pressurized air in the system can
cause product failure or also cause
the filter lid to be blown off, which can
cause death, serious personal injury or
property damage.
5.1

Filter Element Removal

off
1.
Turn
the filter pump and switch off the circuit
breaker to the pump motor.
2.
Open air release valve on top of the filter tank
to release all pressure from inside the tank and
system, see Fig. 8. Close any filter isolation
valves on the system to prevent flooding.
3.
Open the filter tank drain. When the filter tank has
drained, close the drain.
4.
Remove the locking ring/tank top assembly by
pushing on the locking tab and turning the lock
ring counterclockwise.
|
Installation & Operation Manual
5.
Remove the top of the filter. Inspect the tank
o-ring for damage. Clean or replace the o-ring as
necessary.
6.
Remove the filter element from the tank bottom
and clean or replace as necessary.
7.
Place the new or cleaned filter element into the
tank bottom.
8.
Use a silicone based lubricant on the new or
cleaned o-ring and place the o-ring onto the tank
top.
9.
Place the tank top onto the tank bottom. Be sure
the tank halves are seated properly.
10.
Tighten the locking ring, see Section 3.4,
"Locking Ring/Tank Top Assembly Installation".
11.
Follow steps 5 thru 8 under Section 4.1, "New
Pool and Seasonal Start-Up".
Tank Top
Breather Tube
Tank Bottom
Figure 8.
Filter Element Removal
ENGLISH
WARNING
If the breather tube is not fully seated
or is damaged or clogged, trapped
air can cause product failure or also
cause the filter lid to be blown off
which can result in death, serious
personal injury or property damage.
Air
Release
Valve
Locking
Ring
Filter Element