Locking Ring/Tank Top Assembly Installation; Section 4. Start-Up And Operation; New Pool And Seasonal Start-Up - Zodiac Jandy Pro Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 8
ENGLISH
3.4
Locking Ring/Tank Top Assembly
Installation
WARNING
Follow these instructions carefully.
Improper locking ring installation can
cause product failure or also cause the
filter lid to be blown off which can result
in death, serious personal injury or
property damage.
1.
Be certain the o-ring is in position in the upper
tank half. Press the filter lid over the lower half
until seated. Lubricating the o-ring with a silicone
based lubricant will help with installation. See
Fig. 6.
2.
Put the locking ring/tank top assembly on the
lower housing and thread it onto the filter. Turn
the locking ring clockwise until you hear it snap
over the tabs on the lower half of the tank.
WARNING
This filter operates under high
pressure. Ensure that the locking ring
is turned until it clicks past the stop
tab. Failure to properly install the
locking ring or using a locking ring
that is damaged can cause product
failure or also cause lid separation,
which could result in death, serious
personal injury or property damage.
To avoid injury, keep fingers clear of
the lower tank threads and stop tab.
Filter Tank,
Upper Half
Locking
Ring
Locking Ring
Handle
Filter Tank,
Lower Half
Figure 6.
Locking Ring
Jandy
Pro Series, CE Single Element Cartridge Pool & Spa Filter
®

Section 4. Start-Up and Operation

DO NOT operate filter at water temperatures above
105° F (40.6° C). Water temperatures above the
manufacturer's recommendations will shorten the life
span of the filter and void the warranty.
4.1
1.
2.
3.
4.
5.
Tabs
6.
O-Ring
7.
8.
WARNING
NEVER start pump while standing
within five (5) feet of the filter. Starting
the pump while there is pressurized
air in the system can cause product
failure or also cause the filter lid to
be blown off, which can cause death,
serious personal injury or property
damage.
WARNING
NEVER operate the filter system at
more than 50 psi of pressure. Operating
the filter system in excess of 50 psi can
cause product failure or also cause
the filter lid to be blown off, which can
cause death, serious personal injury or
property damage.
CAUTION

New Pool and Seasonal Start-up

Turn off the filter pump and switch off the circuit
breaker to the pump motor.
Check that the filter drain cap and nut are in place
and tight.
Check that the tank locking ring is properly seated
and tight.
Open the pump hair/lint pot lid and fill the pump
basket with water to prime the system. Replace
the pump lid. You may have to do this a few times
on new and seasonal start ups.
Open the air release valve on top of the filter (do
not remove the valve).
Be sure to open any isolation valves that were
installed in the system.
Stand clear of the filter and start the pump to
circulate water through the system. When all the
air is bled from the system and a steady stream of
water starts to come out of the air release valve,
close the valve.
Watch the pressure gauge to be sure that the pressure
does not exceed 50 psi. If the pressure approaches
50 psi, immediately turn the pump off and clean the
filter cartridges. If the pressure remains high after
cleaning the filter, refer to the troubleshooting guide,
Section 8, for possible causes and solutions.
|
Installation & Operation Manual

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Jandy pro cs100Jandy pro cs150Jandy pro cs200Jandy pro cs250

Table des Matières