Test Name
Description
TEST #5
To check: RTD function is good.
RTD Main Oven
Examples:
Temperature
Sensor
1. F6E1
2. No heating (as temperature
"reaches")
Steps
1. Unplug range or disconnect power.
2. Remove door and toe panel to access main control.
3. Verify that ALL connectors are inserted all the way into the main control.
4. Check connector P10 on the main control ACU board. Make sure it is plugged in and fully
seated.
If it is not, make the proper connection and go to step 8.
5. Disconnect the P10 connector and measure indicated temperature sensor resistance value of the
RTD from P10-1 and P10-2 from the harness side. The resistance values should read:
Oven Sensor(s) - Between 931 and 2869 Ω (approximately 1080 Ω at room temperature).
If the temperature sensor does meet the requirements, go to step 8.
6. Remove back panels and ensure the indicated temperature sensor is plugged in properly and
fully inserted. See "Component Locations" section.
If it is not, plug it into the connector and go to step 8.
7. Disconnect the RTD from the main harness and measure resistance from the RTD connector. The
resistance values should read Oven Sensor(s) - Between 931 and 2869 Ω (approximately 1080 Ω
at room temperature).
If it is out of range, the oven sensor is improperly functioning, and needs to be replaced.
8. Reassemble all parts and panels. Plug in range or reconnect power.
9. Wait 3 minutes before checking if there is an error.
If there is an error, go to service mode to check if the error code is F6E1 (Main Oven Over
Temperature Limit).
21
Right Temp Sensor
P10
1
NTC_Boiler