FEATURE DETAILS
B
CL2000
8
F
E
G
H
C
0
D
A.
Use CAT III rated leads or higher.
Do not attempt to measure more than 1000V DC or 750V AC or 2000µA.
B.
Keep hands below line when measuring high current levels.
C.
Auto Power-Off (Apo)
• Device will power off after 30 minutes non-use.
• Turn the dial or press a button to wake.
• Disabled during Max / Min function.
• Holding Select button while turning on disables Auto Power-Off.
D.
Select Functionality Button
• Switch between AC and DC.
• Switch between
and
E.
Hold / Backlight / Worklight
• Press to hold the current input on the display.
• Press again to return to live reading.
• Press for 2 seconds to enable / disable lights.
• Using lights drains the battery significantly.
F.
Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
AT
is displayed on LCD only during auto ranging mode.
G.
Max / Min Hold
• Press to enter Max / Min mode; the largest and smallest
values will be saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum readings.
• Press for 2 seconds to return to live reading and clear
the stored maximum and minimum values.
H. I. Battery Replacement
• When
indicator is displayed on the LCD, batteries must be replaced.
• Remove the back screw and replace 2 x AAA batteries.
All manuals and user guides at all-guides.com
1
J
I
K
10
20
30
40
L
4
A
.
J.
Magnetic Back
• Attach instrument to metal for hands-free use.
K.
Bar Graph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
L.
Relative Reading / Zero Mode
• Press for 2 seconds to enable/disable mode and store reading.
• Display will show the difference between the stored reading and
the live measurement.
FUNCTION INSTRUCTIONS
1
2
6
7
5
3
AC / DC Current (large): < 400A
1.
Features:
HOLD
RANGE
PRESS
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
AC / DC Current (small): < 2000µA
2.
HOLD
RANGE
Features:
• Select AC or DC current source.
Current above 2000µA will damage instrument.
AC / DC Voltage: < 750V AC or 1000V DC
3.
Features:
HOLD
RANGE
PRESS
• Select AC or DC voltage source.
MAX/MIN
ZERO (DC) REL (AC)
MAX/MIN
ZERO (DC) REL (AC)
PRESS
0
10
20
30
40
MAX/MIN
REL
0
10
20
30
40