Problem
Water flows on the
ground.
The temperature in
the appliance is too
low.
The temperature in
the appliance is too
high.
The temperature in
the refrigerator is too
high.
The temperature in
the freezer is too
high.
There is too much
frost.

REPLACING THE LAMP

2
1
Possible cause
The melting water outlet
does not flow in the evap-
orative tray above the
compressor.
The temperature regulator
is not set correctly.
The temperature regulator
is not set correctly.
The door is not closed cor-
rectly.
The product temperature
is too high.
Many products are stored
at the same time.
There is no cold air circula-
tion in the appliance.
Products are too near to
each other.
Food is not wrapped cor-
rectly.
The door is not closed cor-
rectly.
The temperature regulator
is not set correctly.
1.
2.
3.
4.
5.
6.
Solution
Attach the melting water
outlet to the evaporative
tray.
Set a higher temperature.
Set a lower temperature.
Refer to "Closing the
door".
Let the product tempera-
ture decrease to room tem-
perature before storage.
Store less products at the
same time.
Make sure that there is cold
air circulation in the appli-
ance.
Store products so that
there is cold air circulation.
Wrap the food correctly.
Refer to "Closing the
door".
Set a higher temperature.
Switch off the appliance.
Press on the rear hook and at the
same time slide the cover in the di-
rection of the arrow.
Replace the lamp with one of the
same power and specifically designed
for household appliances. (the maxi-
mum power is shown on the lamp
cover).
Slide the lamp cover into its original
position.
Switch on the appliance.
Open the door. Make sure that the
light comes on.