Wacker Neuson RD 7 Notice D'emploi page 50

Masquer les pouces Voir aussi pour RD 7:
Table des Matières

Publicité

Maintenance
5.11 Water Spray Bars
Background
Procedure
5.11.1
a
5.11.2 Start the machine. Activate the spray system and check for free flow
5.11.3 If any of the spray holes are blocked, stop the machine and use a
5.11.4 Rinse the spray bars with clean water and dry with a soft, clean cloth.
All manuals and user guides at all-guides.com
Clogged or dirty spray bars can prevent water from spraying onto the
drums. If water spray is noticeably reduced or absent even though
there is water in the tank, then clean the spray bars.
Follow the procedure below to clean the spray bars.
The spray bars (a) are located behind the drum scrapers.
a
of water through each spray hole (b).
small pointed object (i.e. a stiff piece of wire) to remove the blockage.
NOTICE: The cap (c) and fitting (d) are not removable.
a
c
50
RD 7
d
b
wc_gr007078
wc_tx000295gb.fm