Knife sharpener MS 100
Faults
Behavior in
Basically the following applies:
the event of
1.
Trigger the emergency function immediately in the event of faults that may cause personal injury or
property damage.
faults
2.
Find the cause of the fault.
3.
If troubleshooting requires work in the hazard area, switch the machine off and secure it against
unauthorized restart.
4.
Immediately notify the person in charge on site about the fault.
5.
Depending on the type of the fault, correct the fault yourself or have it corrected by an authorized and
trained expert.
7.2
Table of faults

7.2.1 General faults

Fault
Possible cause
Electric motor without
Electric power supply
function
missing
Defective fuse
Damaged connecting cable
Electric motor turns off
Thermal protection tripped /
after a short period of
active
time.
Cup grinding wheel
Unbalance, parts broken out
vibrates
7.3
Troubleshooting
7.3.1 Replacing the cup grinding wheel
26
All manuals and user guides at all-guides.com
NOTICE!
The table of faults shown below specifies who is authorized to correct the fault.
Remedy
Attach the supply cable to the machine.
Replace the fuse in the control cabinet.
Replace the connecting cable.
Check the plug.
Is the electric motor connected properly as
specified in the circuit diagram?
Replace
IMPORTANT!
The cup grinding wheel must be used as specified by the manufacturer!
The cup grinding wheel may only be replaced by instructed operating
personnel!
The cup grinding wheel may only be used up to the end of the adjusting
range of the adjustable safety plate!
To be corrected by
Operator
Trained electrician
Trained electrician
Trained electrician
Operator
10.03.2009

Publicité