Zero The Display; Taring; Weighing Unit Shi; Parameters And Calibra On - Baxtran SAN Serie Manuel D'usager

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model SAN
03. OPERATION

3.1. ZERO THE DISPLAY

You can press the
measured, within 2% of power up zero. This will usually only be necessary when the pan is empty. When the
zero point is obtained the display will show indicator for zero.
The scale has an automa c rezeroing func on to account for minor dri ing or accumula on of material on
the pla orm. However you may need to press the
shown when the pla orm is empty.

3.2. TARING

Zero the scale by pressing the
Place a container on the pan a value for its weight will be displayed.
Press the
key to tare the scale. The weight that was displayed is stored as the tare value and that value is
subtracted from the display, leaving zero on the display.
The "NET" indicator will be on. As product is added only the weight of the product will be shown.
When the container is removed a nega ve value will be shown. If the scale was tared just before removing the
container this value is the gross weight of the container plus all products that was removed.
The zero indicators will also be on because the pla orm is back to the same condi on it was when the
key was last pressed.
3.3. WEIGHING UNIT SHIFT
Press
key and
mark turn on (kg or lb).
04. PARAMETERS AND CALIBRATION
4.1. ENTER SETTING MODE
To set parameters, first turn on the weighing scales, hold the
"F1 CAL".

4.2. CALIBRATE

A er enter se ng mode, the display will show "F1 CAL". press
pla er, a er STABLE indicator on, press
key to select calibrate weight, a er you select, put the calibrate weight on, a er STABLE indicator on, press
key to sure, scale will auto restart. calibra on finished.

4.3. CHANGE CAPACITY

A er enter se ng mode, the display shows "F1 CAL", press
press
para introducir, presione a tecla
to sure.
4.4. SET RESOLUTION
A er enter se ng mode, the display shows "F1 CAL", press the
key to enter, press the

4.5. CHECK INTERNAL COUNTS

A er enter se ng mode, display shows "F1 CAL", press
to enter, display shows internal counts, press
4.6. SET AUTO POWER OFF TIME
A er enter se ng mode, display shows "F1 CAL", press
key at any me to set the zero point from which all other weighing and coun ng is
key if necessary. The zero indicator will be on.
key to together will change weighing unit in the weight mode, relevant weighing unit
key again, display shows the calibrate weight, you can press
key select current resolu on. Press the
key to rezero the scale if small amounts of weight are
key during self-checking, un l display show
key, display shows "UNLD", empty the
key select , un l display shows "F3 CAP ",
key to enter, press
key display shows "F2 RES " press the
key select , display shows "F4 INP", press
key to return se ng mode.
key select , un l display shows "F5 oFF", press
key to select capacity , press zero key
key confirms.
User's Guide
key
11

Publicité

Table des Matières
loading

Table des Matières