Viking Range 5 Serie Guide D'installation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installations using FLEX BLOWER only:
6. Attach BLOWER SUPPORT LEGS with (4) BOLTS provided.
!
CAUTION: If fl ex blower will be mounted remotely:
Do not use legs alone for support. It may be
necessary to add extra support for the fl ex blower.
Use mounting brackets supplied with the blower.
BLOWER
SUPPORT
LEGS
Installations ducting through left, right, below or rear only:
(Requires purchase of 1-7/8" x 19" to 8" or 10" round transition
or 1-7/8" x 19" duct adapter with rectangular duct cut to
appropriate length.)
7. Use nuts to connect 1-7/8" x 19" rectangular ductwork
connection adapter or 1-7/8" x 19" to 8" or 10" round
transition to housing when installing ductwork.
(4) BOLTS
7
CUT COUNTERTOP OPENING
1. Lay out and cut the cooktop cut-out far enough FORWARD
so downdraft will fi t behind it.
2. Set cooktop in place and slide it as far forward as possible
without exposing an gaps. Center and square it with edges
of countertop.
COOKTOP
Template against back
edge of cooktop.
3. Place the plastic template against the back fl ange of the
cooktop or back edge of slide-in range countertop opening.
Center the template. Trace around template to mark the
downdraft opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of
countertop.