Electrical panel
can be mounted remotely.
Installations ducting through front panel opening only:
1. Remove the HEX NUTS on both CLAMP CHANNELS, and
detach from the unit. Remove the FRONT PANEL COVER.
COVER
PLATE
FLEX
BLOWER
FRONT
PANEL
If blower
discharge is
down, electrical
panel must be relocated.
See Step 5.
Installations using FLEX BLOWER only:
(Purchase Model VDVI600 Flex Blower separately.)
Note: Remove adapter plate from Flex Blower per instructions
packed with blower.
2. Determine its location on FRONT PANEL and whether it will
discharge to the left, right, or down.
Use a combination of COVER PLATES (3" and/or 6" wide) to
close the opening on side(s) of blower.
Insert the blower and cover plates bottom fl anges in the
LOWER CHANNEL, then reinstall the clamp channels. Tighten
the hex nuts to secure blower, panels and clamp channels in
place.
FRONT PANEL COVER
CLAMP
CHANNELS
6 HEX
NUTS
COVER PLATES
(included
with blower)
CLAMP
CHANNELS
LOWER
CHANNEL
REMOTE DISCHARGE
COVER PLATE
PLATE (Purchase Separatly)
FRONT
PANEL
Installations using FLEX BLOWER (in remote location)
or REMOTE BLOWER only:
3. Use the REMOTE DISCHARGE PLATE and determine its
location on FRONT PANEL.
Use a combination of COVER PLATES (3" and/or 6" wide) to
close the opening on side(s) of remote discharge plate.
Insert the remote cover plate and cover plates in the LOWER
CHANNEL, then reinstall the clamp channels. Tighten the hex
nuts to secure the plates and clamp channels in place.
5
8" OR 10" ROUND
COVER PLATES
CLAMP
CHANNELS
LOWER
CHANNEL