The Exterior Wall Duct With Telescopic Inlet Pipe; Installation Of The Wall Duct With Telescopic Inlet Pipe; Fastening The Mounting Sheet; Installation To A Wall Of Inflammable Material - Dru STYLE 3-01 Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Length of inlet pipe
STYLE 3-01
Thickness of wall + 20mm Thickness of wall + 40mm
STYLE 4-01, 5-01 Thickness of wall + 20mm
The tension members fixed to the wall grid can be made
to size after installation
Installation of the standard exterior wall duct
(fig. 1, 3, page 57)
Slide the adjusted inlet pipe (1) through the mounting
sheet (2), with the turned-back edge facing the mark (45º
top left) in the mounting sheet. Slide the sealing ring (3)
and the wall ring (4) around the inlet pipe, paying atten-
tion to the order (see figure). Take the whole and slide
the inlet pipe into the wall opening. Press the mounting
sheet up to the wall. Press the inlet pipe back in such a
way that the end of the pipe is level with the turned-back
edge of the mounting sheet.
From the outside, bring the wall grid with its attached
tension members into the inlet pipe. Bend the tension
members a little outwards, so that they will jam slightly
in the inlet pipe, keeping the grid in its place. Keep the
mark "Top" up when placing the wall grid. Slide the two
fastening clamps (5) over the tension members (6), taking
care that the fastening clamps catch on the turned-back
edge of the mounting sheet. Fix the screw-nuts onto the
tension members and tighten them by hand. Place the fas-
tening clamps onto the horizontal centre line of the inlet
pipe. See also the marks in the mounting sheet.
The exterior wall duct with telescopic inlet
pipe
This is suitable for wall thicknesses of 250 – 440 mm
without shortening the parts of the inlet pipe. By short-
ening the pipe's parts, this exterior wall duct can be
adapted for thicknesses of 70 – 250 mm. The outlet pipe
should be adjusted. The tension members attached to
the wall grid can be shortened after the wall duct has
been mounted. If the telescopic inlet pipe is applied for
wall thicknesses of 70 – 250 mm, both parts of the pipe
should be shortened, i.e.:
• the part of the inlet pipe on the side of the wall grid
equal to the thickness of the wall
• the part of the pipe on the side of the heater to a length
equalling the wall thickness minus 20 mm.
CAUTION: do not cut the pipe parts on the side
where the fastening clamps have been applied.
Installation of the wall duct with telescopic
inlet pipe (fig. 1, 3, page 57)
From the outside, put the wall grid, together with the
attached half inlet pipe into the created wall opening,
keeping "Top" up when placing the wall grid. Slide the
other half of the inlet pipe through the mounting sheet
(2), making sure that the inserted fastening clamps (5)
lie on the horizontal centre line (see the marks in the
Length of outlet pipe
Thickness of wall + 30mm

Fastening the mounting sheet

(fig. 1, 3, page 57)
• Now tighten the screw nuts on the tension members
• Saw or cut the tension members so that they do not
• Drill the hole for the key bolt (7).
• Attach the key bolt and attach the mounting sheet using

Installation to a wall of inflammable material

(fig. 5, 7, page 58, 59)
• On the spot of the duct, create a square opening in the
• In the case of compressible walls, fill up the space all
• In addition, replace the bolt (8) by e.g. a wood screwed
• On the room side, put the heat shield (14) between the
• On the outside of the wall, using 4 screws (16), attach
Installation of the interior
(fig.2, 4, page 57)
11
INSTRUCTIONS FOR INSTALLATION
mounting sheet). They should catch on the turned-back
edge of the mounting sheet.
Attach the sealing ring (3) and the wall ring (4) to the
half inlet pipe (see ffigure for the correct order). Take
the whole and, from the inside, slide the half inlet pipe
through the created wall opening into the part of the
inlet pipe already mounted. While doing so, make sure
the the two tension members (6) stick through the fas-
tening clamps. Press the mounting sheet up to the wall.
Appply the screw-nuts onto the tension members (6) and
tighten them by hand against the fastening clamps (5).
Caution: Level the mounting sheet, make sure that the
inlet pipe goes down towards the outside. (1 cm to 1 m)
and that the wall grid lies straight against the exterior
wall. Then, any condensation will never get into the
heater because of the downwards flow of the pipe.
stick out from the fastening clamps (5).
the bolt (8) and washer (9).
When the appliance is installed to a wall of flammable
material, the wall duct should be executed as follows.
wall (
M mm).
round the opening well, so that the wall cannot be
crushed.
bolt.
mounting sheet (2) and the wall.
siluminplate (15).
The heat shield (14) and the silumin plate (15) are packed
together and are available from your dealer. Assembling
the wall duct is otherwise the same as previously
described.
N.B. To calculate the length of the inlet and outlet pipe,
the thickness of siluminplate (15) should be included.
Take the interior and put it with the bottom edge on the
two supports of the mounting sheet. Keep the interior
balanced and slide the outlet pipe a little bit into the
outlet opening of the interior for support. Now slide the
interior against the mounting sheet, taking care that the
turned-back edge of the mounting sheet fits into the inlet
bush on the back side of the interior and that the bolts
STYLE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Style 4-01Style 5-01

Table des Matières