24 | English
The condition for a correct area/surface calcu-
lation is that the first measured length (in the
example the room height A) is identical for all
partial surfaces.
To restart the wall surface measurement, press
button 11 twice.
Continuous Measurement (Tracking)
(see figure J)
The continuous measurement function (track-
ing) is used for the transferring of measure-
ments, e.g., from construction plans. In contin-
uous measurement mode, the measuring tool
can be moved relative to the target, whereby the
measured value is updated approx. every
0.5 seconds. As an example, the user can move
from a wall to the required distance, while the
actual distance can be read continuously.
For continuous measurements, first select the
length measuring function and then press button
10 until the indicator for continuous measure-
ment
appears on the display. The laser is
switched on and the measurement starts imme-
diately.
Move the measuring tool
until the required distance
value is indicated in the
bottom of the display.
Briefly pressing button 10
ends the continuous meas-
urement. The last meas-
ured value is indicated at the bottom in the dis-
play. Pressing button 10 for several seconds
restarts a continuous measuring run.
The continuous measuring automatically switch-
es off after 5 min. The last measured value re-
mains indicated in the display.
Deleting Measured Values
Briefly pressing button 14 deletes the last indi-
vidual measuring value determined in all meas-
uring functions. Briefly pressing the button re-
peatedly deletes the individual measured values
in reverse order.
In the wall surface measurement mode, briefly
pressing button 14 the first time deletes the last
individually measured value; pressing the button
a second time deletes all lengths B
1 609 929 R53 | (23.7.08)
All manuals and user guides at all-guides.com

Memory Functions

When switching off the measuring tool, the value
in the memory is retained.
In the wall surface measurement mode, the total
surface value can be stored; in the minimum and
maximum measuring mode, the minimum and
maximum value can be stored correspondingly.
Storing individual measuring values within these
functions is not possible.
Storing/Adding Measured Values
As soon as a value has been stored, "M" is in-
dicated in the display and the "+" behind it briefly
flashes.
If a value is already stored in the memory, the new
value is added to the memory contents, however,
only when the measures of unit correspond.
As an example, when an area value is in the
memory and the current measured value is a
volume value, the addition cannot take place.
"Error" briefly flashes in the display.
Subtracting Measured Values
Push the memory subtraction button 12 in order
to subtract the current measured value from the
memory value. As soon as a value has been sub-
tracted, "M" is indicated in the display and the
" – " behind it briefly flashes.
If a value is already stored in the memory, the
new measured value can be subtracted only
when the measures of unit correspond (see
"Storing/Adding Measured Values").
Displaying the Stored Value
indicated in the display, it can be doubled by
pushing the memory add button 3 or set to zero
.
by pushing the memory subtract button 12.
X
Push the memory add but-
ton 3 in order to store the
current measured value –
a length, area or volume
value, depending on the
current measuring function.
Push the memory retrieve
button 2 in order to display
the value stored in the
memory. "M=" is indicated
in the display. When the
memory contents "M=" is
Bosch Power Tools