AUTOMATIC ACCUMULATION
Use this application to automatically add weighing and
counting values to the scale memory and to print values
if a printer is connected.
NOTE: Automatic accumulation must be
enabled. See Setup section on page 10.
When in the automatic accumulation application, the
auto indicator will be shown in the upper right hand
corner of the display.
1.
Place items to be weighed or counted on the scale
platform.
2. Once the stable indicator is shown on the display,
the scale will make a beeping sound.
ACC 1
3.
will be shown on the display and the total
value will be displayed for three seconds. Weighing
or counting value will be stored into memory.
4. Remove items from platform. Display will return to
zero or a negative value.
5. Add additional items to platform. New data will be
added to memory. Continue until all data is added.
6. To recall data and clear data, see sections above.

DYNAMIC WEIGHING

Use this mode to weigh moving items.
1.
Press and release the TARE key
ZERO key
at the same time to enter the
dynamic weighing mode. The hold indicator will
appear in the upper right hand corner of the display.
2. Place item to be weighed on the scale platform.
Once the stable indicator appears, the final weight
will be shown on the display.
3. Press and release the TARE key
ZERO key
at the same time to exit the dynamic
weighing mode.
PAGE 8 OF 36
OPERATION CONTINUED
RS-232
To use the RS-232 port, connect the gray RS-232 adapter
to the gray RS-232 cable on the display indicator.
(See Figure 9)
SPECIFICATIONS
RS-232 output of weighing data:
• Code:
• Data Bits:
• Parity:
• Baud Rate: 600bps – 900bps selectable.
RS-232
and the
Pin 1: VB
and the
CONTINUOUSLY OUTPUT PROTOCOL
Weighing Mode
-- HEADER 1 --
Counting Mode
P
HEADER1: ST=STABLE, US=UNSTABLE
HEADER2: NT=NET, GS=GROSS
Figure 9
RS-232 Cable
RS-232 Adapter
ASCII
8 data bits
No Parity
(9-PIN D TYPE CONNECTOR)
Pin 2
RXD
Input
Pin 3
TXD
Output
Pin 5
GND
9 Pin D Connector
Scale
Computer/Printer
Pin 2:
Pin 3:
Pin 5:
Check Weighing Output
Pin 4: Vcc 5v (Output)
Pin 5: Com (Ground)
Pin 6: Ok (Output)
Pin 7: Low (Output)
Pin 8: Hi (Output)
Pin 9: Beep (Output)
-- HEADER 2 --
-- WEIGH DATA --
C
S
:
-- QTY --
Receiving Data
Transmission Data
Signal Ground
Pin 3
Pin 2
Pin 5
k
g
CR LF
-- WEIGH UNIT --
TERMINATOR
p
c
s
CR LF
-- QTY UNIT --