Manual Accumulation - Uline H-5836 Mode D'emploi

Masquer les pouces Voir aussi pour H-5836:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.
Key in the low limit. Use the G/N key
ACC/TTL key
to move the active digit left and right.
Use the TARE key
8. Press the ZERO key
9. Press the UNIT key
CHECK WEIGHT OPERATION
1.
Place item to be weighed on the scale platform.
Weight will be shown on the display. Scale will beep
if weight is within specified high-low range. Indicators
on right of the display will show if weight is above (HI),
below (LO) or within (OK) the specified range.
CLEAR CHECK WEIGHT
1.
Press the UNIT key
the same time until
2. To clear the high limit, press the ZERO key
00000
will be shown on the display with the last
digit blinking.
3. Press PCS key
to clear out the value.
4. Press the ZERO key
shown on the display.
5. Press the TARE key
display.
6. To clear the low limit, press the ZERO key
00000
will be shown on the display with the last
digit blinking.
7.
Press the PCS key
8. Press the ZERO key
9. Press the UNIT key
PAGE 7 OF 36
OPERATION CONTINUED
and the
to increase the numeric value.
to confirm.
to exit to the weighing mode.
and the PCS/SET key
SEt H
is shown on the display.
Set H
to confirm.
Set L
until
is shown on the
to clear out the value.
to confirm.
to exit to the weighing mode.
ACCUMULATION
Use this mode to measure the cumulative weight or
counting values of a sequence of items. The maximum
number of samples is 99 entries or the scale weight
capacity.

MANUAL ACCUMULATION

1.
Follow steps above to weigh or count items on the
scale platform.
2. Once the stable indicator is shown on the display,
press the ACC/TTL Print key
on the display and the total value will be displayed
for three seconds. Weighing or counting value will
be stored into memory. If a printer is connected, the
data will print.
at
3. Remove items from platform. Display will return to
zero or a negative value.
.
4. Add additional items to platform.
5. Once the stable indicator is shown on the display,
press the ACC/TTL Print key
added to memory. Continue until all data is added.
RECALL DATA
will be
1.
With nothing on the platform, press and release the
ACC/TTL Print key
of items stored to memory. The number of
accumulated values will be displayed,
.
followed by the total accumulated value for three
seconds.
CLEAR DATA
1. To clear data stored to memory, press and hold the
G/N key
same time.
ACC 0
2.
accumulated values will be cleared from memory.
NOTE: Weight on platform must be equal to
or greater than minimum weight in order for
accumulation mode to operate accurately.
to display the total value
and the ACC/TTL Print key
will be shown on the display. All the
ACC 1
.
will be shown
. New data will be
#
ACC
,
at the
0621 IH-5836

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

H-5837

Table des Matières