Addi onal clearances 
Check on whether local codes supersede these 
clearances. 
Avoid termina on loca ons near a dryer vent. 
Avoid termina on loca ons near commercial 
cooking exhaust. 
You must install a vent termina on at least 12 
inches from the ground. 
RU80i, RU98i 
The vent for this appliance shall not terminate 
Over public walkways; or 
Near soffit vents or crawl space vents or other 
area where condensate or vapor could create a 
nuisance or hazard or cause property damage; or 
Where condensate or vapor could cause damage 
or could be detrimental to the opera on of 
regulators, relief valves, or other equipment. 
Important considera ons for loca ng vent 
termina on under a soffit (ven lated or unven lated 
or eave vent; or to a deck or porch) 
Do not install vent termina on under a soffit vent 
such that exhaust can enter the soffit vent 
Install vent termina on such that exhaust and rising moisture 
will not collect under eaves.  Discolora on to the exterior of 
the building could occur if installed too close. 
Do not install the vent termina on too close under the soffit 
where it could present recircula on of exhaust gases back 
into the combus on air intake part of the termina on. 
(0.30 m ) to 
an inside 
 
corner 
36"
12"
V
12"
INSIDE
CORNER
V
(0.30 m) between  
terminals at same 
level 
(50 mm) between 
terminals at same level 
12"
(0.30 m) to an 
inside corner 
V
(1.52 m) 
ver cally 
between 
60"
terminals 
V
KB Series Manual 
RU80e, RU98e 
(0.91 m) to ven lated 
or unven lated soffit 
or eve vent; or to a 
36"
deck or porch 
2"
(1.52 m) ver cally 
between terminals 
60"
(1.52 m) 
between  
60"
terminals at 
different levels 
V
(0.61 m) to wall or parapet 
24"
V
 
12"
(0.30 m) between  
V
V
terminals at same 
level 
V