Flue Installa on with Centrotherm Ven ng (indoor models only)
Install the ven ng termina on according to the diagrams and instruc ons below.
•
Comply with the exhaust clearances found in the Rinnai Opera on and Installa on Manual.
•
Only one appliance can be a ached to the vent system.
•
Install the system in according to the Centrotherm installa on instruc ons.
•
Use the 3"/5" concentric to twin pipe adaptor and 3" diameter ven ng.
•
The vent termina on and air intake must be in the same pressure zone.
•
Do not exceed maximum straight vent length with number of elbows as shown in the tables on the next
page.
•
Maintain the clearances shown in the figures below.
WARNING
14
DO NOT use PVC on the exhaust ven ng. PVC is allowed on the intake only.
Ver cal Termina on
Horizontal Termina on
KB Series Manual
5"
Vent
11
"
Intake
Op onal