Rinnai RU80i Manuel D'installation Et D'utilisation page 35

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
Temperatures Available with a Controller  
The water heater can deliver water at only one temperature se ng at a  me.  The available temperatures are 
provided below.  A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water. 
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the "On/Off" bu on 
for 5 seconds while the water heater is OFF. 
Fahrenheit °F 
Celsius  °C 
Temperature se ngs from 125‐140 °F (52‐60 °C) are available by se ng switch 6 to ON in the SW1 tan  
switches.  These models have a default maximum temperature of 120° F (49° C) and an op on (switch 6)  to 
increase the maximum temperature to 140 °F (60 °C).   
**  These se ngs require the MCC‐91‐2 controller.  When the MCC‐91‐2 controller is connected, these higher 
temperatures are available on all controller models in the system. Use of an MCC‐91‐2 controller in a 
residen al dwelling will reduce the warranty coverage to that of a commercial warranty applica on. 
WARNING
These temperatures are sugges ons only: 
Alternate Temperature Se ngs  
A different range of temperature se ngs is available by se ng switches 2 and 3 of the SW2 dip switch (white) to 
ON.  The table below shows the se ngs available with the MC‐91‐2 and MCC‐91‐2 controller. 
WARNING
Fahrenheit °F 
Celsius  °C 
 
Temperature Se ngs Available 
98  100  102  104  106  108  110  115  120 
37 
38 
39 
40 
DO NOT adjust the other switches unless specifically instructed to do so. 
MC‐91‐1, MCC‐91‐1, MC‐100V‐1, and BC‐100V‐1 controllers are not compa ble with 
Alternate Temperature Se ngs.  Alternate Temperature Se ngs are for commercial 
applica ons only. 
DO NOT use the MC‐91‐1, MCC‐91‐1, MC‐100V‐1, or BC‐100V‐1 controllers when dip 
switches 2 and 3 (white) are in the ON posi on.  
Alternate Temperature Se ngs Available 
110  115  120  125  130  135  140  145  150  155  160  165  170  175  180  185 
43 
46 
49 
52 
MC‐91‐2 
41 
42 
43 
46 
Kitchen  120 °F (49° C) 
Shower  98 ‐ 110 °F (37 ‐ 43 °C) 
Bath Fill  102 ‐ 110 °F (39 ‐ 43 °C) 
54 
57   60 
63 
MCC‐91‐2 
KB Series Manual 
125
130
135
140
49 
52 
54 
57   60 
66 
68 
71 
74 
150
160
185
** 
** 
** 
66 
71 
85 
77 
79 
82 
85 
35 

Publicité

Chapitres

Table des Matières
loading

Table des Matières