C50S • C80S • C120S • C150S • C200S
• Proper electrical, water and sewage net-
work connections must be ensured at the
installation location.
• To decrease heat loss attributable to the
hot water pipe, the appliance should be
installed the closest possible to the wa-
ter withdrawal locations. Hot water pipes
should be added heat insulation.
• Before mounting, check the position of
the hanging brackets.
5. CONNECTION TO THE WATER SUPPLY
The container and assemblies required for its operation must be
connected to the water network according to igure 11.3.
5.1.
AIt is forbidden to connect the appliance using a hose.
For cold and hot water connections, steel or red copper pipe rated for 0.6 MPa
nominal pipeline pressure, heat resistant plastic pipe rated up to min. 100 °C or
flexible connection may equally be used. When connecting to a copper pipeline,
the use of insulating spacers is compulsory. One spacer must be inserted on the
hot water pipe of the container immediately, while the other one on the cold wa-
ter pipe, between the installed assemblies and the copper water pipeline. If no
spacer is used at the connections, we neither provide guarantee for failures at-
tributable to the corrosion of the threaded tank pipes, nor assume liability for
damages caused by the same.
The spacer is not included; you can order it under the following part numbers, de-
pending on the dimensions:
• 1/2" spacer: 1252122514, (C50S, C80S, C120S)
• 3/4" spacer: 1252122513. (C150S, C200S)
30
It is forbidden and dangerous to expose the container
to pressures higher than
the allowed operating pressure!