Abicor Binzel FES-200 W3 Mode D'emploi page 43

Masquer les pouces Voir aussi pour FES-200 W3:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FES-200 W3
5.2 Filter dedusting (dedusting by rotation)
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Disconnect all electrical connections.
CAUTION
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with locally filtered
forced ventilation.
• Check and wear your personal protective equipment.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask Class P3, protective
gloves and safety shoes.
• Nobody without personal protective equipment may stay near the dust collecting drawer when it is being filled with the
separated dust.
NOTICE
• This procedure must be carried out when the system is not in operation.
• Use only dry and oil-free compressed air (max. 4 bar).
• If the input pressure is >5 bar, the excess pressure escapes sidewise through the pressure relief valve.
1
1
Seal plug
Fig. 4
Filter dedusting
Proceed as follows:
 Fig. 2 Functional description on page EN-11
1 Put the fume extraction system on the floor.
2 Switch off the fume extraction system by turning the rocker switch (11) (0 position).
BAL.0335.0 • 2019-08-16
2
2
Filter dedusting (dedusting by rotation)
5 Functional description
3
4
3
Compressed air connection
4
Valve lever
EN - 13

Publicité

Table des Matières
loading

Table des Matières