Intended Use - fisair DIPHUSAIR-MT2 Manuel D'installation Et De Maintenance

Humidificateurs isothermiques par injection de vapeur sèche
Table des Matières

Publicité

1.2 Safety requirements and electromagnetic compatibility
This product is
EN60730-2-14.
This product complies with EMC Directive 2014/30/EU, EN61000- 6-2, EN6100- 6- 4
The product may be exposed to interference above the limits of industrial immunity if:
-
The product or its wiring is located near to a radio transmitter.
-
Excessive electrical noise occurs on the mains supply.
-
Cellular telephones and mobile radios may cause interference if used within approximately
one metre of the product or its wiring. The actual separation necessary will vary according to
the power of the transmitter.
-
Power line protectors (ac) should be installed if mains supply noise is likely.
-
Protectors can combine filtering, suppression, surge and spike arrestors. For a copy of the
declaration of conformity contact Spirax Sarco.

1.3 Intended use

Referring to the Installation and Maintenance Instructions, name-plate and Technical Information
Sheet, check that the product is suitable for the intended use / application.
i)
Check material suitability, pressure and temperature and their maximum and minimum values.
If the maximum operating limits of the product are lower than those of the system in which it
is being fitted, or if malfunction of the product could result in a dangerous over pressure or
over temperature occurrence, ensure a safety device is included in the system to prevent such
over-limit situations.
ii) Determine the correct installation situation.
iii) Spirax Sarco products are not intended to withstand external stresses that may be induced by
any system to which they are fitted. It is the responsibility of the installer to consider these
stresses and take adequate precautions to minimise them.
iv) These actuators are not suitable for use as safety devices according to the pressure equipment
directive 2014/68/EU or the machinery directive 2006/42/EU.
1.4 Access
Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting
to work on the product. Arrange suitable lifting gear if required.
1.5 Lighting
Ensure adequate lighting, particularly where detailed or intricate work is required.
1.6 Hazardous environment around the product
Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of
temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery.
Do not use the actuators in explosive atmosphere according the ATEX directive 2014/34/EU.
4
marked. It complies with LV Directive 2014/35/EU, EN60730-1,
AEL3 Electric Linear Actuators