Technical data
Technical data
General technical data of the CPX terminal
Electric characteristic values
– Nominal operating voltage DC
– Permissible voltage fluctuations
– Operating voltage in the case of a tap by
the contact rail 24 V
(integrated polarity protection)
– Residual ripple (within tol.)
– Voltage drop bypass time U
– Intrinsic current consumption at nominal
operating voltage
– Undervoltage monitoring U
– Overvoltage monitoring U
– Operating voltage when tapping contact
rail 5 V and 0 V
– Electrical isolation between V
(or 5 V CBUS) and V
– Electrical isolation channel – internal bus
– Electrical isolation channel - channel
– Potential reference for channels
– Max. power supply CH0 (load current)
– Max. power supply CH1, CH2
(load current per channel)
– Max. load current per unconnected
voltage U
(auxiliary supply)
VAL
38
and 0 V
VAL
VAL
VAL
VAL
VAL
EL,SEN
VAL
CPX-FVDA-P
CPX system description
(P.BE-CPX-SYS...)
[V DC]
24
[%]
-15 ... +20
[V DC]
20.4 ... 28.8
[Vss ]
2
[ms]
2
[mA]
for valves (from U
for electronics (from U
U < 20 V for t > 200 ms
U > 29.5 V for t > 200 ms
[V]
5 ± 5%
[V rms]
min. 500
Yes, for intermediate supply
No
V
VAL
[A]
1.5
[A]
0.5 (12 W lamp load)
[A]
2.5
):
typ. 65
VAL
): typ. 25
EL/SEN