Error 278: PWR_SUP_LVW / current too low
Error 279: LvWedge Voltage / Voltage too
low
Error 290: Supervision, EL6080 NOVRAM,
Load: FB Read/Write busy for t>200ms
Error 291: Supervision, EL6080 NOVRAM,
fbWrite.bError
Error 292: Supervision, EL6080 NOVRAM,
fbWrite.bWcState
Error 293: Supervision, EL6080 NOVRAM,
Write: FB busy for t>200ms
Error 294: Supervision, EL6080 NOVRAM,
Load: FB Read/Write busy for t>200ms
Error 295: EL6080 NOVRAM, Cyclic Access
not possible
Error 296: E-Puller Motor Driver Error.
Error 297: E-Puller Calibration Error.
Error 310: LV-Wedge Controller Error. Restart
Machine
Description
In LvWedge()
Power Supply lacks in weld current. Power
Supply needs maintenance or low setting in
Energy parameter
In LvWedge()
Error occured in Voltage Measurement.
Check connection between Wedge and Wed-
ge holder. Wedge is broken or damaged.
Can not read Meter Hours during Startup of
Supervision Extension.
Shutdown SEAMTEK W-AT Machine and
restart.
fbWrite Error in INIT State of EL6080.
Shutdown SEAMTEK W-AT Machine and
restart.
Invalid Working Counter of EL6080.
Shutdown SEAMTEK W-AT Machine and
restart.
Can not write Meter Hours during Startup of
Supervision Extension. Delete Error Message
in i-Tab. If Error reappears shutdown SEAM-
TEK W-AT Machine and restart.
Can not read Meter Hours during Startup of
Supervision Extension.
Shutdown SEAMTEK W-AT Machine and
restart.
Can not store and load data. Restart machi-
ne if Error is recurrent.
Driver error (E-Puller). Check for Overload.
material jammed, increase clamp clea-
rance
Check E-Puller machine setup.
LV-Wedge PID Controller has Error. Restart
Machine.