Leister SEAMTEK W-900 AT Mode D'emploi page 42

Table des Matières

Publicité

Réf.
Niveau Texte d'information
erreur
228
2
229
2
230
2
231
2
232
2
233
2
234
2
235
2
236
2
237
2
238
2
239
2
240
2
241
2
242
2
243
2
244
2
245
246
247
2
42
Error 228: Error UPWM-Axis. Busy during
WpPush-State
Error 229: Error UPWM-Axis. Busy during
Cp-State
Error 230: Open File in Write Machine
Settings
Error 231: Write CSV Line in Write Machine
Settings
Error 232: Close File in Write Machine
Settings
Error 233: Error UPWM-Axis. Busy during
RW State
Error 234: Error UPWM-Axis. Busy during
Cp-State
Error 235: Error UPWM-Axis. Busy during
RW State
Error 236: Error positioning UPWM-Axis.
Position can not be reached
Error 237: Error UPWM-Axis. Busy during
WpAbs-State. INOUT_SMALLSTEP.
Error 238: Error UPWM-Axis. Busy during
WpAbs-State. IN_ABSOLUT
Error 239: LV-Wedge Resistance / Tempera-
ture too high
Error 240: Open File in Read Recipes
Error 241: Read CSV Line in Read Recipes
Error 242: Close File in Read Recipes
Error 243: Error positioning X-Axis. Position
can not be reached
Error 244: Error positioning Y-Axis. Position
can not be reached
Error 245: Error X-Axis. Busy during OUT-
State
Error 246: Error X-Axis. Busy during IN-State
Error 247: Error Y-Axis. Busy during IN-State
Description
In UPWM_AxisWPush()
Movement not possible, UPWM-Axis is alrea-
dy operating
In UPWM_AxisCp()
Movement not possible, UPWM-Axis is alrea-
dy operating
In SettingsWrite()
Error Machine Settings Open File
In SettingsWrite()
Error Write CSV Line Machine Settings
In SettingsWrite(), Error Closing File
In UPWM_AxisManRw()
Movement not possible, UPWM-Axis is alrea-
dy operating
In UPWM_AxisManCp()
Movement not possible, UPWM-Axis is alrea-
dy operating
In UPWM_AxisRw()
Movement not possible, UPWM-Axis is alrea-
dy operating
In UPWM_AxisMove()
check if parameter settings are correct or
UPWM-Axis is mechanically blocked
In UPWM_AxisCpMinusPush()
Movement not possible, UPWM-Axis is alrea-
dy operating
In UPWM_AxisCpMinusPush()
Movement not possible, UPWM-Axis is alrea-
dy operating
In LvWedge()
Wedge requires recalibration, change wedge
In RecipesRead(), Error Recipes Open File
In RecipesRead (), Error Read CSV Line
Recipes
In RecipesRead (), Error Closing File
In X_AxisMove()
check if parameter settings are correct or
X-Axis is mechanically blocked
In Y_AxisMove()
check if parameter settings are correct or
Y-Axis is mechanically blocked
In X_AxisOut()
Movement not possible, X-Axis is already
operating
In X_AxisIn()
Movement not possible, X-Axis is already
operating
In Y_AxisIn()
Movement not possible, Y-Axis is already
operating

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Seamtek w-2000 at

Table des Matières