VISUAL GUIDE Assembly
I
a.
c.
d.
f.
COMBINED THERAPY / NEBULIZER CONFIGURATION
integrated nebulizer port ID 20,3 mm / AD 22,4 mm
Nebulizer
PLEASE NOTE:
In combination with nebulizers, it is important to ensure that the
RC-Cornet
PLUS/TRACHEO with and without the RC-Cornet
®
PLUS NEBULIZER SET is as securely fitted as it would be if
the nebulizer mouthpiece was attached. In other words, during
inhalation you should not see any inhalation solution flowing
outside of the product combination. To this end, pay attention
to the respective interior diameter (ID). Also, please read the
instructions for use of your nebulizer and your inhalation device,
as well as of the corresponding medication.
RC-Cornet
PLUS NEBULIZER SET
®
Article no. 2651 | PPN 111 443 990 049
* Depending on the application deviations in the deposition data are possible.
*
1
If there is a possibility of heat development during the mist inhalation,
the RC-Cornet
PLUS TRACHEO should not be used.
®
22 | EN
22 | EN
b.
e.
g.
RC-Cornet
PLUS,
®
RC-Cornet
PLUS TRACHEO
*1
®
®
ID18,16 mm
*
ID 17,7 mm
ID 22 mm
INSTRUCTIONS Assembly
I
Please wash your hands before assembly.
a. Connect the one way valve with the adapter.
b. Connect the mouthpiece centered with the adapter.
For using the device please follow the instructions
for use (see pages 18 and 19).
c. Remove the cleaning aid from the valve tube.
d. Connect the valve tube with the adapter and make
sure that the centering dot clicks into the cut-out of
the adapter.
e. Guide the piece into the body. Make sure that the
arrow on the adapter and on the body are aligned.
f. Check the valve tube position. It should not be kinked.
g. Reattach the body lid.
COMBINED THERAPY / NEBULIZER CONFIGURATION
Combining RC-Cornet
PLUS therapy with a standard ISO
®
nebulizer improves delivery of your nebulized medication
and reduces the total treatment duration. Furthermore the
effectiveness of both therapies is improved.
Connect the RC-Cornet
®
first attach the nebulizer in a straight direction to the adapter.
To detach the nebulizer from the adapter, pull it straight out
and off.
IMPORTANT: Please do not "shake" the nebulizer. This may
damage the device.
Please always use setting 1 of RC-Cornet
therapy. This setting opens your airways and stabilizes them.
Please inhale and exhale only through the device. The treatment
duration corresponds with the nebulizer period.
NOTE: The NEBULIZER SET is available for non ISO nebuli-
zers. The nebulizer and the NEBULIZER SET are not included.
They can be purchases separatly. For more information visit
www.cegla.de
PLUS to your nebulizer. To do so,
PLUS for combined
®
EN | 23
EN | 23