We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly installed. Please read this
Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary-preventing device.
TAKEX is not responsible for damage or losses caused by accident, theft, Acts of God (including lightning), abuse, misuse, abnormal usage, faulty
installation or improper maintenance.
PRODUCT DESCRIPTION :
The dual zone outdoor PIR is an automatic switch which uses passive infrared sensor to detect infrared (body temperature) emitted from a human body. (Suitable for
indoor/outdoor)
Analyze possible problems according to the following table.
TROUBLESHOOTING :
Trouble
(1) The power supply is not connected (including broken
(2) The detection area is blocked by an object (which may
The sensor does not
detect anything
(3) Unsuitable detection area settings (including detection
(4) Approximately 1 minute has not passed since turning the
(1) Unsuitable detection area settings (including detection
The sensor sometimes
(2) The detection lens is covered with dust or water droplets.
does not detect anything
(3) Unsuitable detection or pulse count settings.
(1) Unstable power supply voltage.
(2) Something is moving within the detection area, or there are
(3) A source of electrical noise (broadcasting station, amateur
The sensor generates
(4) Direct or reflected light such as sunlight or headlights
an alarm, although
there are no people
within detection area
(5) The sensor is mounted on an angle (the horizontal zone is
(6) Cars or motorcycles are sometimes detected at the edge of
The operation LED is on,
(1) Wiring failure, broken wire, or short-circuit.
but connected devices are
(2) Check that connected devices are operating correctly.
not operating.
If normal operation cannot be restored by these means, contact either the dealer from whom you bought the unit or TAKEX directly.
SPECIFICATIONS :
Model
OMS-12FE
Detection system
Passive infrared
When horizontal detection
Coverage
Angle : 180°, Detection distance : 40'(12m)
Horizontal zone : 14 zones
Horizontal : L/R 90° (selectable)
Detection distance : 10' ~ 40'(3 ~ 12m)
Coverage adjustment
(by adjusting vertical angle of downward curtain)
Supply voltage
9 to 28 VDC (non-polarity)
Current consumption
20mA MAX
Dry contact relay output N.C./N.O. selectable
Alarm output
· Contact capacity : 30V (AC/DC), 0.2A MAX.(Resistive load)
· Contact operation : Detection time(2sec)
Dry contact relay output N/C
Tamper output
· Contact capacity : 30V (AC/DC), 0.1A MAX.(Resistive load)
Red LED
Operation LED
Blinking at warming / Lighting at alarm (cancellation possible)
Pulse count
1 / 2 / 3 / 4 times (selectable with DIP switch)
Sensitivity adjustment
Approx. 30% - 170% (By Potentiometer)
Functions
Back Tamper, Trouble alarm, Low voltage monitoring
Connection
Terminals
-4°F to + 122°F (-20°C to + 50°C)
Ambient temperature
Mounting position
Indoor / Outdoor
Ingress protection
IP54 (equivalent) (Wall mount)
Weight
16.5oz (470g)
Appearance
Body : resin (white) / Lens : resin (grey)
Optional
Pole attachment : BP-32
※ Specifications and design are subject to change without prior notice.
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by
TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration
to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts
returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges
rendered for product repairs made after our Warranty Period has expired.
Instruction Manual OMS-12FE
Check
wiring), or the power supply voltage is low.
include glass).
distance).
power ON.
distance).
sudden changes in temperature.
radio station, etc.) is nearby.
sometimes shines onto the sensor itself or into the detection
area.
tilted).
the detection area.
Downward zone : 14 zones
(1) Check the power wiring, and ensure appropriate power
supply voltage. → [7. WIRING]
(2) Remove obstacles.
(3) Readjust detection area. → [3. DETECTION AREA]
(4) Wait approximately 1 minute.
(1) Readjust detection area. → [3. DETECTION AREA]
(2) After wiping with a damp soft cloth, wipe off water droplets.
(3) Ensure appropriate detection and pulse count settings.
→ [6. SETTING]
(1) Ensure appropriate power supply voltage.
(2) Remove the problem object.
(3) Change the mounting location or remove the noise source.
→ [2. PRECAUTIONS]
(4) Change the mounting location, or location of the reflective
item.
Readjust detection area.
Use the area masking sheet to hide zones for which
detection is not required. → [3. DETECTION AREA]
(5) Ensure the sensor is not mounted at an angle.
→ [3. DETECTION AREA]
(6) Reduce the set distance. Readjust detection area.
→ [3. DETECTION AREA]
(1) Connect wiring correctly.
(2) Investigate with reference to the instruction manuals of the
connected devices.
MAINTENANCE
• To clean the device, use a soft, wet cloth and then wipe off
any water drops. If the device is particularly dirty, dip the
soft cloth in the water that contains a weak neutral
detergent. Wipe the device gently with the cloth, then wipe
off any detergent that remains. Do not use substances such
as thinner or benzene.
(The plastic parts may deform, discolor or change their
properties.)
• Perform operation checks on a regular basis.