Selecting the operating mode:

Press
button
start
Sauna
80
°C
start
Evaporator
50
°C
start
Infrared
50
°C
80
start
Radiator
100
°C
Blower
OFF
prog. pre-select
EN
prog. pre-select
max. operat. time
28
5
5
48
%
5
48
%
°C
5
80
%
OFF
OFF
02:00:00
Operating mode "sauna"
Adjusted temperature 80 °C
If a button is not pressed for 5 seconds, it will start operating in the
selected operating mode (counter displayed on the right at the top).
Attention: It is not possible to change from one operating mode to
another during sauna operation! If this is desired, the cabin must be
switched off first and then restarted.
Operating mode "evaporator"
Adjusted temperature 50 °C and relative hum. 48 %
Operating mode "infrared"
Adjusted temperature 50 °C, relative hum. 48 % and temperature
for infrared surface heating 80 °C
Operating mode "infrared radiator"
The left power regulator is set to 100 % and the right one to 80 %.
If only one regulator is connected, only one value is displayed.
Operating mode "blower"
Display only shown with active blower function =
YES (see item 6.4)
hold the MODE button down for 2 sec.
(while counter display greater than 0)
Max. operating time according to STANDARD EN60335-2
private operation 6 hours
commercial operation 12 hours