WIKA RLS-1000 Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Specifications
Overview of floats (models RLS-1000, RLS-2000, RLS-3000)
Form
Outer
∅ D
EN
Cylinder 55 mm
Cylinder 55 mm
Cylinder 44 mm
Cylinder 44 mm
Cylinder 30 mm
Cylinder 25 mm
Ball
52 mm
Model RLS-5000
Specifications
Switching power
Permissible temperatures
Medium
Ambient
Storage
Process pressure
Medium density
22
Height
Operating
H
pressure
65 mm
≤ 3 bar
(≤ 43.5 psi)
55 mm
≤ 3 bar
(≤ 43.5 psi)
44 mm
≤ 3 bar
(≤ 43.5 psi)
52 mm
≤ 16 bar
(≤ 232 psi)
36 mm
≤ 10 bar
(≤ 145 psi)
17 mm
≤ 16 bar
(≤ 232 psi)
52 mm
≤ 40 bar
(≤ 580 psi)
Normally open,
normally closed:
Change-over contact: AC 230 V; 40 VA; 1 A
-40 ... +80 °C (-40 ... +176 °F)
-40 ... +80 °C (-40 ... +176 °F)
-40 ... +80 °C (-40 ... +176 °F)
max. 16 bar (232 psi)
≥ 750 kg/m
Medium
temperature
≤ 120 °C
(≤ 248 °F)
≤ 80 °C
(≤ 176 °F)
≤ 80 °C
(≤ 176 °F)
≤ 150 °C
(≤ 302 °F)
≤ 150 °C
(≤ 302 °F)
≤ 80 °C
(≤ 176 °F)
≤ 150 °C
(≤ 302 °F)
AC 230 V; 100 VA; 1 A
DC 230 V; 50 W; 0.5 A
DC 230 V; 20 W; 0.5 A
3
WIKA operating instructions models RLS
Density
Material
≥ 800 kg/m³ PVDF
≥ 500 kg/m³ PP
≥ 500 kg/m³ PP
≥ 750 kg/m³ 316Ti
≥ 850 kg/m³ 316 Ti
≥ 500 kg/m³ Buna /
NBR
≥ 750 kg/m³ 316 Ti

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rls-2000Rls-3000Rls-5000Rls-6000

Table des Matières