Maintenance
B. Remove the Water Trough
Remove the upper thumbscrew.
While supporting the water trough remove the
thumbscrew from beneath the water trough.
Remove the water trough from the bin area.
UPPER THUMBSCREW
18
LOWER THUMBSCREW
C. Remove the Ice Damper
Remove thumbscrew from bin switch cover.
Support ice damper and then pull bin switch cover
and ice damper forward to remove.
2. SUPPORT ICE DAMPER THEN
SLIDE RIGHT SIDE FORWARD TO REMOVE
D. Remove the Water Distribution Tube
Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
Loosen the two outer screws and pull forward on the
distribution tube to release.
1. REMOVE THUMBSCREWS
Water Distribution Tube Removal
Section 4
1. REMOVE THUMBSCREW
2. PULL DISTRIBUTION TUBE
FORWARD TO REMOVE
Part Number 040002909 5/13