Section 2
Water Supply and Drain Line Sizing/Connections
Location
Temperature
Ice Making
40F (4C) Min.
Water Inlet
90F (32C) Max.
Condenser Water
Inlet
40F (4C) Min.
90F (32C) Max.
Condenser Water
Drain
Bin Drain
ICE THICKNESS ADJUSTMENT
The ice thickness can be adjusted to three levels.
1. Pull forward on the bottom of the bracket until clear
of the tab.
2. Slide the bracket over the desired tab and release.
•
The center position is the normal factory setting.
•
To increase bridge thickness, raise the water level.
•
To decrease bridge thickness, lower the water level.
Thicker
Bridge
Part Number 040002909 5/13
Water
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
20 psi (137.9 kPA) Min.
150 psi (1034.2 kPA) Max.
---
---
Factory
Thinner
Default
Setting
Bridge
Water
Pressure
3/8" Female Pipe
3/8" Female Pipe
1/2" Female Pipe
---
1/2" Female Pipe
---
1/2" Female Pipe
WATER/DRAIN CONNECTIONS
A. Potable Water Inlet
B. Drain
C. Condenser Water Inlet - (Water-cooled Only)
D. Condenser Water Outlet - (Water-cooled Only)
Installation Instructions
Ice Machine
Tubing Size Up to Ice
Fitting
Machine Fitting
3/8" (9.5 mm) minimum
Thread
inside diameter
3/8" (9.5 mm) minimum
Thread
inside diameter
U310 Only
1/2" (12.7 mm)
Thread
minimum inside diameter
1/2" (12.7 mm) minimum
Thread
inside diameter
1/2" (12.7 mm) minimum
Thread
inside diameter
U310 Only
C
D
A
B
11