Mount to 4 in. Housing - item # 53185142
1
Turning off the power
□ Make sure the power is turned off at the source
to the recessed can housing where the fixture will
be installed. Remove the existing bulb and trim,
revealing the socket.
nOTiCe: Stick the replacement label
on the inner wall of the recessed housing
before installation.
3
Connecting the cables
□ Plug the cable connector on the socket adapter (E)
into the connector on the LED light module (D).
E
D
2
Connecting the socket adapter
□ Screw the medium base (E26) socket adapter (E) into
the socket in the recessed housing.
E
4
Pushing the LED light module into
the recessed can
□ Carefully push the LED light module (D) into the
recessed can housing until the trim is flush with the
ceiling surface.
nOTiCe: Select the preferred color temperature
of the light before pushing the LED light module
into the recessed can housing.
D
8

adjusting the Color Temperature of the Light

This downlight allows you to customize the color temperature of the light anywhere from warm white to bright white.
□ Choose your favorite correlated color temperature (CCT) from three options: 2700K, 3000K, or 4000K.
□ Move the toggle switch on the side of the LED light module to make your selection before pushing the LED light module into the
recessed can housing.
nOTiCe: The factory setting for the correlated color temperature (CCT) is 2700K, which is the warmest white light.
item # 53185142

Care and Cleaning

CaUTiOn: Before attempting to clean fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from
the fuse box.
□ Clean the fixture with a soft, dry cloth.
□ Do not use cleaners with chemicals, solvents, or harsh abrasives

Troubleshooting

WarninG:
Before doing any work on the fixture, disconnect power to the light fixture.
Minor problems often can be fixed without the help of an electrician.
Problem
Possible Cause
The fixture will not light.
The power is off.
The circuit breaker is off.
There is a bad connection.
There is a defective switch.
The fuse blows or the circuit breaker trips
The wires are crossed or the power
when the light is turned on.
wire is grounding out.
item # 53186142
Solution
Ensure the power supply is on.
Ensure the circuit breaker is in the on position.
Check to ensure proper wire connections are made.
Contact a qualified electrician.
Contact a qualified electrician.
Check the wire connections.
Contact a qualified electrician or call ETi Solid State
Lighting, inc. service 1-855-384-7754.