SETUP
AIR SOURCE
The HAUSSMANN 21° framing nailer is designed to operate on clean, dry,
compressed air, regulated at 70-110 PSI. The preferred system would include a filter,
a pressure regulator, and an automatic oiler located as close to the tool as possible.
Within 15 feet (5 m) is ideal. Do not use bottled air or gases. Please see below:
Regulator
Air hose
All compressed air contains moisture and other contaminants that can harm the
internal components of the tool. An air line filter will remove most of these and
significantly extend the life of the tool. Ensure the in-line oiler has sufficient oil.
If an in-line oiler is not available, place 2 drops of oil into the tool's air inlet at
the beginning of each workday. More than this will be expelled from the tool's
exhaust during firing.
Air fitting: The framing nailer should be equipped with a 1/4" NPT male 'quick
connector'. To prevent accidental cycling even though disconnected, the tool
must always be connected to the air supply in such a way that all air pressure
in it is released when the coupling is disconnected.
CAUTION:
All air line components (including hoses, pipe, connectors, filters, & regulators,
etc.) must be rated for a minimum working pressure of 150 PSI or 150% of the
maximum system pressure, whichever is greater.
Disconnect the tool from the air supply before performing maintenance, clearing a
jammed fastener, leaving the work area, moving the tool to another location, or
handing it to another person.

PREPARING THE TOOL

1. After reading and understanding this entire manual, connect tool to the air
supply.
CAUTION:
 Keep tool pointed away from yourself and others at all times.
 Always disconnect tool to air supply before loading fasteners.
 Do not load fasteners with trigger or safety pressed.
 Always wear approved safety glasses, and hearing protection when preparing
or operating the tool.
Oiler
Filter
Air connector
Fig.2