TEST RUN

Before using the air compressor for the first time, complete
a test run as follows:
1. Turn the power switch to the OFF position. Plug the pow-
er supply cord into a power supply socket. Start the air
compressor by turning the power switch to the ON posi-
tion. The pressure gauge reading will slowly rise as pres-
sure increases inside the air tank. When the gauge reading
reaches ~125 PS
I, the pressure switch will automatically
turn the power off. This indicates the compressor is work-
ing normally.
2. Turn the power switch to the Off position, unplug the pow-
er supply cord and release the air in the tank by pulling
on the safety valve. At this point proceed to the next step
(daily operations).
Note: If the Air Compressor is not working properly, the
pressure gauge will indicate that there is a decrease in
pressure in the air tank. If there is an air leak from the com-
pressor the pressure in the air tank decreases, the pressure
switch resets and the motor automatically turns back on.
If you detect an air leakage, turn the power switch to the
Off position, release the air from the tank by pulling on the
safety valve. unplug the power supply cord and contact
Customer Support for Assistance.
AVERTISSEMENT
Air compressor surfaces become hot during operation.
DO NOT touch hot surfaces, because they can cause
severe burns.
Do not touch the air compressor's cylinder head. During
operation, the cooling fins of the cylinder head and
delivery pipe become hot.
Allow the air compressor to cool before touching it.
DO NOT place a storage cover on the unit during
operation. Only place a cover on the air compressor
after it has thoroughly cooled down.
Customer Support 503-253-7308 M-F, 8am-4:30pm PST | iwata.support@iwata-medea.com | www.iwata-airbrush.com/blog/contact-us
Flying objects can cause injury to the eyes, head and
other parts of the body.
Air-powered equipment and power tools are capable
of propelling items (metal chips, fasteners and
particulates) at high speed into the air and could result
in injury.
Always wear approved head and eye protection.
Never point the air stream at any part of your body, or at
another person or animal.
When operating the air compressor, make sure all other
people and animals maintain a safe distance.
Do not move the air compressor when the air tank is
under pressure.
Never use the air hoses to pull or move the air
compressor.
Keep the air compressor on a flat surface.

DAILY OPERATION

Starting The Compressor:
1. Turn the power switch to the OFF position.
2. Attach an air hose to a 1/4" Industrial Male Quick Con-
nector. Attach the air hose to the air compressor female
connector
3. Close the drain valve.
4. Have air filter attached
5. Plug the power supply cord into a power supply socket.
6. Turn the power switch to the ON position.
7. Let the motor run and tank fill until motor turns off.
8. To regulate the air flow:
While the air compressor is running, turn "On" your tool
and turn the regulator knob to the right increasing the
pressure. Turn the pressure up until the desired pressure is
reached.
9. Operate air tool normally.
Do not exceed (1) hour of (non-stop) continuous running.
Shutting Down The Compressor:
1. Turn the power switch to the OFF position.
2. unplug the power supply cord.
3. Reduce the pressure in the air tank through the air sup-
ply hose. drain the remaining air and water from the drain
valve.