7 MAINTENANCE

(by an enabled technical service centre)
7.1 MAINTENANCE
The stove may only be maintained by an enabled
technical service centre.
Prior to effecting any maintenance operation,
adopt the following precautions:
-
Make sure that the stove is completely cold.
-
Make sure that the ashes have gone out
completely.
-
in Directive 89/391/EEC.
-
Make sure the mains power is off at the master
power switch.
-
Ensure that the power supply cannot be
restored accidentally. Remove the power plug
from the socket.
-
Always use proper tools.
-
Once maintenance or repair activities are
completed, reinstall all the protections and
reactivate all the safety devices prior to
restarting the system.
7.1.1
This must be done at least once a year, or every 4
tons of pellets.
If it is not kept clean, the stove may experience
problems including:
-
poor combustion
-
blackened glass
-
blocked brazier, accumulated ash and pellets
-
ash and excessive encrustations on the heat
7.1.2 Servicing the stove
This must be done at least once a year, or whenever
the stove itself displays the maintenance required
message.
The technician must:
-
thoroughly clean the fumes circuit
-
check the condition and tightness of all seals
-
check the condition and cleanliness of all
internal components
-
check the tightness and cleanliness of the
-
remove all pellet residue remaining in the pellet
tank
-
check that the stove is operating properly
MAINTENANCE
-
reset any warnings and alarms (the manual
reset thermostats are at the back of the stove
next to the power cable outlet).
7.1.3
At least once a season you must remove the right
side of the stove and clean with an ash vacuum
and a brush, the smoke box. To do this you need
to access the compartment by removing the two
inspection plugs as shown in Figure (7.1)
problems and is performed according to the
BEATRICE model, in order to ensure its durability,
maintenance, and cleanliness, the structure of
the exhaust circuit for stove combustion products
must be taken into account along with the
presence of a compartment for collecting soot that
is inside of it. Maintenance and cleaning must be
replaced if necessary on the access panels to the
combustion products circuit.
door frame is due to combustion temperatures and
ash and does not prevent the normal operation of
the stove.
Maintenance
poses
The possible discoloration of the internal
no
particular
fig. 7.1