8.4
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Use a filter or disposal bag when extracting
hazardous materials!
► Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room, the air renewal rate L within the room
must be sufficient. The volume of air dis­
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
x air renewal rate L
R
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There­
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
8.5
Extracting wet materials/liquids
Remove the filter or disposal bag!
Recommendation: use special wet filter
(NF-CT).
The dust extractor stops automatically when
the maximum level is reached.
After wet extraction, allow the main filter to dry!
CAUTION
Escaping foam and fluids
► Switch off and empty the machine immedi­
ately.
8.6
After finishing work
► Only versions with AutoClean: Clean the
main filter automatically or manually (see
chapter 8.2).
► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Close off the extractor opening [1-2] using
the sealing plug [1-1].
). Observe all the rele­
W
WARNING
Hazardous dust
Damage to the respiratory passage
► Wipe down the mobile dust extractor and
clean all accessories thoroughly using the
extractor (inside and out) before removing
from the working area.
► Parts that you were not able to clean thor­
oughly must be sealed in an airtight plastic
bag prior to transportation.
► Wear a dust mask!
The machine shall be stored indoors on­
ly.
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
9
Service and maintenance
WARNING
Risk of injury, electric shock
► Always disconnect the mains plug from the
socket before performing maintenance
work on the machine!
► All maintenance and repair work which re­
quires the motor housing to be opened
must only be carried out by an authorised
service workshop.
Customer service and repair only through
manufacturer or service workshops: Please
find the nearest address at: www.festool.com/
service
EKAT
4
5
3
2
1
Only use original Festool spare parts! Order No.
at: www.festool.com/service
Damaged safety devices and components must
be repaired or replaced in a recognised special­
ist workshop, unless otherwise indicated in the
operating manual.
Observe the following instructions:
The manufacturer or an instructed person
must perform a dust test at least once a
year to determine whether the filter is
damaged, the machine is sealed properly
English