TROUBLESHOOTING

Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this troubleshoot-
ing guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby's Toll Free Number 1-800-263-2629 for assistance.
PROBLEM
Unit does not work
Air from unit does not feel cold
enough
Air conditioner cooling but room
is too warm- ice forming on cool-
ing coil behind decorative front
Air conditioner cooling but room
is too warm- NO ice forming on
cooling coil behind decorative
front
Air conditioner turns on and off
rapidly
Noise when unit is cooling
Water dripping INSIDE when unit
is cooling
Water dripping OUTSIDE when
unit is cooling
Remote sensing deactivating
prematurely
Room too cold
POSSIBLE CAUSE
Power is out
The plug is not plugged in prop-
erly
Plug current device tripped
Control is off
Room temp. below 17°C (62°F)
Temp. sensing element touching
cold coil (behind air fi lter)
Temp. set too high
Compressor shut off by changing
modes
Outdoor temp. below 17°C
(62°F)
Air fi lter may be dirty
Thermostat too cold for night-
time cooling
Dirty air fi lter - air restricted
Temp. is set too high
Air directional louvers positioned
improperly
Front of unit blocked (i.e. by
drapes), restricting air distribu-
tion
Doors, windows, registers etc.
open, cold air escaping
Unit recently turned on in hot
room
Dirty air fi lter - air restricted
Outside temp. extremely hot
Air movement sound
Window vibration
Improper installation
Unit removing large quantity of
moisture from humid room
Remote control not located with-
in range
Remote control signal obstructed
Set temperature too low
19
SOLUTION
Wait for power to return
Plug in properly
Press the reset button after
resolving problem
Turn control ON and set to de-
sired setting
Will not cool until room temp.
rises above 17°C (62°F)
Straighten tube away from coil
Reset to a lower temp.
Wait approx. 3 minutes and
listen for compressor to restart
when in cool mode
To defrost coil, set to FAN ONLY
Clean fi lter as per instructions
Set temp. to a higher setting
Clean air fi lter
Set to lower temp.
Position louvers for better air
distribution
Clear blockage in front of unit
Close doors, windows, registers
allow additonal time to remove
"stored heat" from room
Clean air fi lter
Set fan speed to higher setting
to bring air past cooling coils
more frequently
This is normal. If too loud, set to
slower fan setting
Poor installation-refer to instal-
lation instructions or check with
installer
Tilt air conditioner silghtly to the
outside to allow water drainage
This is normal during excessive-
ly humid days
Place remote control withing 8
meters (20 Ft.) and 180° radius
of front of the unit
Remove obstruction
Increase set temperature

Publicité