Electrical Connections Table - V2 City9 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
PLEASE NOTE: If not used, the normally closed inputs (STOP, PHOTO, EDGE) must be jumpered with the commands
common line COM (-)
If not used, the open limit switch FCA (A) and close limit switch FCC (B) inputs must be jumpered with the limit switch
common line (D)
L1
Antenna
L2
Antenna shield
Opening command for a standard connection device
L3
with switch normally open.
Pedestrian opening command for a standard
L4
connection device with switch normally open.
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
L7
Edge. Switch N.C. or resistive rubber edge
L8
Commands common (-) line
24 VAC power output for photocells and other
L9 - L10
accessories
L10 - L11 Power supply for functional test TX photocell
ELECTRICAL CONNECTION TABLE
J1
8
C1
Motor open
C2
Motor common
C3
Motor close
D1 - D2 Courtesy light timer activation switch
D3 - D4 230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
A
Limit switch open. N.C. switch
B
Limit switch closed. N.C. switch
C
NOT USED
D
Limit switch common (-) line
J1
NOT USED

Publicité

Table des Matières
loading

Table des Matières