Step 4: Close the housing

• Close the cover and loosely tighten the cover fixing screws
• The tamper switch must be closed.
• The front of the housing must be in the final position for the subsequent tests.

Step 5: Test the system

• Reopen the housing by removing the screw on the bottom of the detector and taking off the
front housing panel.
• The receiver component must remain in installer mode so that the control panel doesn't
trigger a tamper alarm.
Setting the microwave range:
• Set the microwave range to the minimum.
• Enable tampering or insert batteries.
• Replace the cover.
• Walk test (deactivates after 30 minutes).
o Green = IR detection.
o Yellow = Microwave detection.
o Red = Confirmed IR and microwave detection.
• Increase the microwave range until lit red.
Do not increase the range beyond the surveillance partition. Otherwise the motion
detector may react to motion in surrounding areas.
Note
Installation